Remarks for mounting the SECU-BAR 125 
SECU-BAR 125 uses an insulated housing for DIN-rail mounting. The insu-
lation  provides  utmost  safety  during  the  installation 
–  short circuits via the 
housing, indirect touching of live conductors is impossible. 
Please, adhere  to all  local  safety regulations and standards (like DIN  VDE 
0100, VBG4, etc.) and follow the instructions of the manufacturer and of the 
plant manager. 
The  wiring  of  the  connection  terminals  is  done  with  the  provided  self-
clearing spring-clips and plus-minus screws. 
First  of  all  install  the  wiring  to  the  SECU-DATA  xxxx,  and  afterwards  the 
connections  to  the  not  intrinsically  safe  power  supply.  Snap  the  SECU-
DATA 125 simply on to the DIN-rail. 
 
Wiring of the SECU-DATA xxxx: 
1.  For  the  wiring  use  round  wires  of  type:  0,08 
– 2.5 mm
2
  cross  sec-
tion,  AWG  28 
–  12,  flame  propagation  characteristics  as  per  IEC 
60332-1-2, within a round cable to ensure the water protection 
2.  Strip the wires off app. 5-6 mm 
3.  Depress each of the levers of the terminal block  (Type WAGO se-
ries  256,  ATEX  certified  for  EEx-i  applications)  with  a  small  screw 
driver 
4.  Put  the  stripped  wire  end  into  the  terminal  and  release  the  lever 
again 
5.  Close the SECU-DATA xxxx housing again and mount it to the final 
location with the supplied screws in the provided holes of the hous-
ing.  Take  care  for  correct  positioning  of  the  sealing  elements.  For 
metal  base  planes  ensure  that  there  is  some  space  between  the 
RF-antenna  and  the  metal  material  to  maintain  the  best  effective 
range of the RF connection. 
 
Remark:
 After delivery one cable gland is sealed waterproof with a cap. 
This is useful if only one cable gland shall be used.