Operation
  In order to avoid distortions or mismatching, which could damage the microphone or
any audio device connected, the product must only be connected to suitable micro-
phone inputs. Please refer to the connection values under “Technical data” for more.
Only use a suitable, shielded microphone cable for connecting the microphone. Using
other cables could cause interferences.
Never point the microphone at the sound outlet of speakers as this may result in feed-
back which can cause damage to the speakers and the connected amplifier.
•  Mount the vibration damper to a microphone stand.
•  Insert the microphone with shaft into the vibration damper.
•  Place the included windscreen on the microphone if required.
•  Turn off the audio device to which you wish to connect the microphone.
•  Connect the audio device’s input to the XLR connection on the microphone.
•  On your audio device, activate the phantom power supply for the microphone.
•  Turn on your audio device.
•  Adjust the sensitivity of the audio device to the microphone using the corresponding input level 
control (see the user manual of your audio device).
Maintenance and cleaning
The studio microphone is maintenance-free.
Use a soft, dry or slightly damp cloth for cleaning.
Never use any aggressive solvents or chemical solutions as these may cause damage to the hous-
ing surface.
Disposal
   
Electronic  devices  are  resources  and  must  not  be  disposed  of  through  household 
waste!
 
 At  the  end  of  its  service  life,  dispose  of  the  product  in  accordance  with  applicable 
regulatory guidelines.
Technical data
Impedance ....................................................200 ohm
Frequency range ..........................................20-20000 Hz
Sensitivity  .....................................................-38 dB.
Max. input level SPL ....................................136 dB
S/N ratio.........................................................77 dB
Phantom power supply ...............................48 V/DC
Directivity ......................................................Cardioid
Membrane .....................................................18 mm gold diaphragm
Operating principle ......................................Condenser microphone
Dimensions....................................................175 x 47 mm 
Weight ............................................................315 g 
 
 Operating Instructions
 AT-100 Studio microphone
Item no. 1216213
Intended use
The microphone is intended for converting acoustic signals (sound waves) into electric signals.
The low level audio output signal must only be connected to suitable microphone inputs on audio 
devices.
Use of the product other than for its intended use described here is prohibited and will result in 
damage to the product. It may also related to hazards such as short-circuit, fire, etc.
Read this user manual completely before first use and keep it for future reference.
The product as a whole must not be modified or altered!
Please follow all safety instructions under all circumstances.
This product complies with the statutory national and European requirements. All company names 
and product names are trademarks of their respective owners. All rights reserved.
Delivery content
•  Microphone
•  Vibration damper
•  Wind screen
•  Operating instructions
Safety instructions
First read the complete user manual as it contains important information on using the
product.
In  case  of  damage  caused  by  non-observance  of  these  operating  instructions,  the
warranty gets void! We are not liable for any consequential damage!
We  are  not  liable  for  property  damage  or  injuries  caused  by  improper  use  or  non-
observance of safety instructions! Such circumstances will void the warranty!
 
•  For safety reasons, it is not permitted to alter and/or modify the microphone.
 
•   The microphone must be powered by a device with a phantom power supply (48 V/
DC) only.
 
•   Also follow the safety instructions of the device to which the microphone is con-
nected.
 
•   Do not expose the product to extreme temperatures, strong vibrations or dripping or 
splashing water.
 
•  Use the product in temperature climates only, do not use in the tropics.
 
•  The product is not a toy; keep it out of the reach of children.
 
•   Do not leave packaging material unattended, as children could use it as a toy creat-
ing hazardous situations.
 
•   Handle the product with care; impacts, blows or falling from even low heights can 
cause damage.
 
•  Observe all other safety instructions in each chapter of these instructions.
 
•   For installations in industrial facilities, follow the accident prevention regulations for 
electrical systems and equipment of the government safety organization or the cor-
responding authority for your country.
 
•   In case of doubts regarding the correct installation or if you have any questions not 
being answered in these operating instructions, please contact our technical sup-
port or any other expert.
Features
•  High-quality condenser microphone for recording music and nearly all sound sources
•  Vibration camper for decoupled connection to microphone stands
•  Broad frequency spectrum
•  Low inherent noise
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent 
the technical status at the time of printing.  
© Copyright 2014 by Conrad Electronic SE.