Examples: 
1.  Set chopper mode to SPI Mode:  
 
 
AM 0 
ENTER 
2.  Read out the actual mode: 
 
 
 
Am 
ENTER 
3.  Change Microstep resolution ¼ of max. resolution: 
AZ 2 
ENTER 
Example for test move: 
 
Different accelerations and velocities 
AA 500, AV 50000, AV –50000  
try other AA 0…8000, AV 0…400000 
 
Max. current – test of torque 
AA 500, AV 50000, AC 200 
 test torque manually 
 AC 20 
 test torque 
 
Read and set position 
AV 0, AR, AA 500, AV 50000, AR, AP 0, AR 
5.4.2  Commands ‘A’ and ‘a’: Set or read back acceleration 
The ‘A’ command sets the acceleration that is used in conjunction with the ‘V’ command. Setting the 
acceleration  parameter  to  0  enables  the  step/direction  interface  (this  is  also  the  factory  default 
setting). Setting the accelerations parameter to any value greater than zero disables the step/direction 
interface  and  allows  moving  the  motor  via  the  RS485  interface  using  the  ‘V’  command.  The 
acceleration  parameter  is  given  in  microsteps/s².  This  setting  can  also  be  stored  permanently  using 
the ‘W’ command. 
The ‘a’ command outputs the actual acceleration setting. 
5.4.3  Commands ‘C’ and ‘c’: Set or read back motor current 
The ‘C’ command sets the maximum motor current. The parameter range is 0..31, according to table 
3.6.  This  setting  should  not  be  changed  while  the  motor  is  moving.  The  power-on  setting  for  this 
command is set by the DIP switches. 
The ‘c’ command outputs the actual motor current setting. 
5.4.4  Commands ‘D’ and ‘d’: Set or read back mixed decay setting 
The  ‘D’  command  sets  the  mixed  decay  behavior.  The  parameter  can  be  0,  1  or  2.  Setting  the 
parameter  to  0  disables  mixed  decay.  Setting  it  to  1  enables  mixed  decay.  Setting  the  mixed  decay 
parameter  to  2  enables  mixed  decay,  but  mixed  decay  will  automatically  be  disabled  whenever  a 
StallGuard  reference  search  is  started.  This  setting  can  also  be  stored  permanently  using  the  ‘W’ 
command. 
The ‘d’ command outputs the actual mixed decay setting. 
5.4.5  Commands ‘E’ and ‘e’: Read motor driver error status 
In chopper mode 0, eight error flags are provided by the motor driver. The E or e command provides 
a value that has to be interpreted as follows: 
Bit 
Name 
Function  
Remark 
OT 
Overtemperature 
“1” = driver chip off due to overtemperature 
OTPW 
temperature prewarning 
“1” = driver chip prewarning temperature exceeded 
UV 
driver undervoltage 
“1” = undervoltage on VS 
OCHS 
overcurrent high side 
3 PWM cycles with overcurrent within 63 PWM cycles 
OLB 
open load bridge B 
Open load detection can occur at fast motion also. 
OLA 
open load bridge A 
Open load detection can occur at fast motion also. 
OCB 
overcurrent bridge B low side  Short circuit detected. Please check motor wiring. 
OCA 
overcurrent bridge A low side  Short circuit detected. Please check motor wiring. 
Table 5.4: Failure readout in SPI mode 
In the other two modes there is only one error flag and thus the command only outputs ‘0’ or ‘1’: 
1: short circuit or overtemperature 
0: no failure