Functional description 
En = 1 and Lap = 0: Using the selected timebase, the stopwatch outputs the current time 
(CurT) to AQ.  
En = 1 and Lap = 1: The stopwatch leaves AQ at its last value when Lap = 0. This value is 
recorded as LapT for stopwatch pause time.  
En = 0 and Lap = 1: The stopwatch pauses counting time. It outputs LapT to AQ.  
En = 0 and Lap = 0: The stopwatch outputs the current time (CurT) to AQ.  
A signal at R sets the AQ value to 0.  
Setting the Par parameter 
View in programming mode (example): 
 
To change the timebase, press   to move the cursor to "10ms". Press OK and now the 
timebase can be selected. Press  or   to select another timebase. To confirm your 
selection, press OK. 