Advantech ADAM-6050 18-Channel Isolated Digital I/O Modbus TCP Module ADAM-6050-BE Scheda Tecnica

Codici prodotto
ADAM-6050-BE
Pagina di 272
179
Chapter 7  
Figure 7.5: Scaling Function of Analog Input Mode
Local Digital Input Channel (DI)
After you choose DI as input mode, select the channel by the Channel 
combo box. The value of the selected digital input channel will directly 
be the input of condition. If the value of the selected digital input channel 
is logic high, the condition result is logic True. If the value is logic low, 
the condition result is logic False
Local Counter Input Channel (DI_Counter)
After you choose DI_Counter as input mode, select the channel by the 
Channel combo box. The count value of the selected counter input chan-
nel will directly be the input of condition. Like the Analog Input condi-
tion, select the appropriate condition for that input channel by the 
Condition combo box and the Value text box. The condition will com-
pare the value read from the counter input channel with the value set by 
the Value text box. If condition is satisfied, the condition result is logic 
True. Otherwise, the condition result is logic False.