Wr Rademacher DuoFern 35000462 Multi-purpose dimming actuator Flush mount 1-channel Max. range (open field) 100 m 35000462 Scheda Tecnica

Codici prodotto
35000462
Pagina di 2
1.  General safety instructions
2.  Correct usage
Only use the DuoFern Universal Dimmactuator (fm) for connection and control 
of the following electric lamps:
 
 Conventional bulbs
 
 Lamp transformers with:
-  Leading-edge phase control or
-  Trailing-edge phase control
The use of defective equipment can lead to personal
injury and damage to property.
Never use defective or damaged equipment. Please contact 
our Customer Service department in the event of faults
Mortal danger in the event of connecting unsuitable
devices.
Overloading the Universal Dimmactuator (fm) by connecting 
unsuitable devices can lead to overheating, short circuits and 
fire under certain circumstances.
 
 For this reason, only connect lamps to the DuoFern 
Universal Dimmactuator (fm) as specified in the “Correct
usage” chapter.
4.1  Functional description
The DuoFern Universal Dimmactuator (fm) can be used to integrate and 
control electric lamps within a DuoFern network. In order to use the functions 
of the corresponding DuoFern controllers (e. g. DuoFern manual transmitter 
standard), you must connect the DuoFern Universal Dimmactuator (fm) to 
the DuoFern network. 
The two buttons can be used to switch the Universal Dimmactuator (fm) 
between connect and disconnect mode. A bi-coloured indicator light shows 
whether the DuoFern actuators connected to the Universal Dimmactuator 
(fm) have received and confirmed the control commands.
4.  General view
3.  Incorrect use
Never use the DuoFern radio system and its components for remote control 
of devices and systems with heightened safety-relevant requirements or 
a heightened risk of accident. Such use would require additional safety 
equipment. Observe the respective statutory regulations for the installation 
of such systems.
IMPORTANT
Do not install the DuoFern Universal Dimmactuator (fm) outdoors. 
The following types of lamp may not be used as they cannot be
dimmed:
 
Fluorescent lamps
 
Low-energy bulbs
 
LED lamps
Antenna
Connection terminals 
Disconnect button
DuoFern environmental sensor Item no. 3200 00 64
DuoFern manual central operating unit Item no. 3481 00 60
RolloTron Pro Comfort DuoFern Item no. 1523 45 11
DuoFern Standard manual transmitter Item no. 3248 03 66
DuoFern Wall controler Item no. 3216 02 11
Manual control (on/off)
Random function
Manual operation (on/off)
Timer (on/off)
Automatic solar function (on/off)
Solar program
Automatic dawn function (on/off)
Automatic dawn function
Automatic dusk function (on/off)
Automatic dusk function
Mode change
Connection test
Radio code
Runtime
4.4  Overview of switching commands and actions
Switching commands
Mode 1
Mode 2
UP # 
100 %
0 %
STOP
0 %
0 %
DOWN #
0 %
100 %
Automatic dawn function
100 %  
0 %
Automatic dusk function
0 %
100 %
Solar program
0 %
0 % 
Up with current dimming 
direction 100%
100%
STOP*
Up with current dimming 
direction 0%
STOP*
0%
STOP with current dimming 
direction 100%
STOP*
STOP*
STOP with current dimming 
direction 0%
STOP*
STOP*
Down with current dimming 
direction 100%
STOP*
100 %
Down with current dimming 
direction 0%
0%
STOP*
#   If the last intermediate state has been reached, then the Universal Dimm-
  actuator (fm)  stops here. No intermediate state is stored upon connecting  
  the mains.
*  The current brightness of the lamp is stored as the intermediate state.
NOTE
 
Automatic commands are dimmed to the target value as quickly as 
possible.
 
The dimming time for manual commands can be configured via the 
running time feature.
 
Use mode 2 when operating the DuoFern Universal Dimmactuator (fm) 
in combination with roller shutters. 
Manual control behaviour for use with a local switch.
Brief press
 
= switches ON/OFF, no stop when reaching the inter-
 
  mediate state
Press and hold   =  dims alternately (on to 100% and off to 0%), the new 
 
  dimmed value will be stored as the intermediate  
 
  value.
Random function
The actuator can process random function switching commands. If a switch-
ing command is received which is to be delayed by the random function, then 
processing of the switching command is delayed by up to 30 minutes. The 
LED flashes green once per second during the delay period.
4.3  Functional characteristics
4.2  The installation principle
Indicator light
Connect button
Flush-mounted box
DuoFern Universal  
Dimmactuator (fm)
 
Antenna
Cover plate
Connecting cables
0 %    
100%
Item no. 3500 04 62
VBD 562-2 (04.13)
DuoFern Universal Dimm-
actuator flush-mounted (fm)
Installation and
operating instructions
EN
2.  Correct usage
Operating conditions
 
Only use the DuoFern Universal Dimmactuator (fm) in dry rooms.
 
For the electrical connection a 230 V/50 Hz power supply, together  
with a site-provided isolating device (fuse), must be available at the 
installation site.
 
The installation and operation of the DuoFern radio system and its com-
ponents (e. g. DuoFern Universal Dimmactuator (fm)) is only permitted 
for those systems and devices where a malfunction in the transmitter 
or receiver would not cause a danger to persons or property or where 
this risk is already covered by other safety equipment.