15.  Initial commissioning with the help of the installation wizard
An installation wizard is available in order to help you 
configure  the  RolloTron  Comfort  DuoFern  quickly  and 
easily. The wizard automatically guides you through the 
configuration process for initial commissioning or after 
software reset (see page 73).
Quitting the installation wizard. 
Pressing the [ M ] key for 2 seconds causes the installation 
wizard to be cancelled prematurely.
Readiness for operation
The RolloTron Comfort DuoFern is ready for use as soon as 
the installation wizard has finished. 
In addition, you can individually customise your settings 
and make changes at any time from the main menu and 
the system settings menu.
Additional information about configuring the end 
points
The end points must be configured in order for the roller 
shutters to stop at the desired upper and lower positions. 
It  is  imperative  that  both  end  points  are  configured, 
otherwise malfunctions may occur.
IMPORTANT
 
If the RolloTron Comfort DuoFern is operated without 
an end point setting, the drive will continue to run 
for as long as one of the two control keys is actuated.
 
The automatic functions remain blocked until the end 
point setting is configured.
 
Do not set the upper end point right up to the limit 
stop.
 
Please ensure that the belt is not excessively slack when 
reaching the lower end point.
 
Release the key promptly and never allow it to extend 
beyond the respective end point. Failure to do so can 
cause overloading and may damage the roller shutters 
and / or drive.
NOTE
 
After a period of time it may be necessary to reconfig-
ure the end points as the belt may elongate during the 
process of operation due to stretching.