3. Installation and Initial Startup 
4. Important Safety Warning (SAVE THESE INSTRUCTIONS) 
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity 
controlled indoor area free of conductive contaminants. (See the specifications for the 
acceptable temperature and humidity range.) 
NOTE: Before installation, please inspect the unit. Be sure that nothing 
inside the package is damaged.   
 
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and 
avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances 
such as space heaters or furnaces. 
Placement & Storage Conditions 
Install the UPS in a protected area that is free of excessive dust and has adequate air flow. 
Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT 
operate the UPS where the temperature and humidity is outside the specific limits. (Please 
check the specs for the limitations.) 
CAUTION! Do not attach non-computer-related items, such as medical equipment, 
life-support equipment, microwave ovens, or vacuum cleaners to UPS. 
CAUTION! Do not plug the UPS input into its own output. 
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages 
or any other liquid-containing vessels on or near the unit.   
 
CAUTION! In the event of an emergency, press the OFF button and disconnect the power 
cord from the AC power supply to properly disable the UPS. 
CAUTION! Do not attach a power strip or surge suppressor to the UPS. 
CAUTION! If the UPS is with metal chassis, for safety purpose, grounding is a must during 
UPS installation in order to reduce leakage current below 3.5mA. 
Connect to Utility and Charging 
Plug in the AC input cord to the wall outlet. For the best results, 
suggest to charge the battery at least 4 hours (4 Stunden) 
before initial use. The unit charges its battery while connecting 
to the utility. 
Attention hazardous through electric shock. Also with disconnection of this unit from the 
mains, hazardous voltage still may be accessible through supply from battery. The battery 
supply should be therefore disconnected in the plus and minus pole at the quick connectors of 
the battery when maintenance or service work inside the UPS is necessary. 
4 hours
CAUTION! Servicing of batteries should be performed or supervised by personnel 
knowledgeable of batteries and the required precautions.    Keep unauthorized personnel away 
from batteries.   
 
Connect the Loads 
Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the 
power switch of UPS unit, then devices connected to the UPS will be protected by UPS unit. 
CAUTION! When replacing the batteries, use the same number and type of batteries. 
CAUTION! Internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell battery. 
CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or 
mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. 
CAUTION: NEVER connect a laser printer or scanner to the 
UPS unit. This may cause the damage of the unit.   
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 
CAUTION! A battery can present a risk of electric shock and high short circuit current. The 
following precaution should be observed before replacing batteries: 
 
Connect Modem/Phone/Network for Surge Protection (Only for the model with 
RJ-11/RJ45)  
1) 
Remove watches, rings, or other metal objects. 
2) 
Use tools with insulated handles. 
Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of 
the UPS unit. Connect from “OUT” outlet to the computer with another phone line cable.   
3) 
Wear rubber gloves and boots. 
4) 
Do not lay tools or metal parts on top of batteries. 
 
5) 
Disconnect charging source prior to connecting or disconnecting batteries terminal. 
 
Connect Communication Cable (Only for the model with RS-232 port) 
5. Software Download & Installation (Only for the model with 
communication port) 
To allow for unattended UPS shutdown/start-up and status monitoring, connect the 
communication cable one end to the RS-232 port and the other to the communication port of 
your PC. With the monitoring software installed, you can schedule UPS shutdown/start-up 
and monitor UPS status through PC. 
Please follow steps below to download and install monitoring software: 
1. Go to the website http://www.power-software-download.com 
2. Click ViewPower software icon and then choose your required OS to download the software.   
Turn On/Off the Unit 
3. Follow the on-screen instructions to install the software. 
Turn on the UPS unit by pressing the power switch.    Turn off the UPS unit by pressing again 
the power switch.    
4. When your computer restarts, the monitoring software will appear as an orange plug icon 
located in the system tray, near the clock.