Table 4. 
ROADM Cards Specifications 
Specification 
40-WSS-C/ 
40-WSS-CE 
40-DMX-C/ 
40-DMX-CE 
40-WXC-C 
40-MUX-C 
Management 
Card LEDs: 
Failure (FAIL) 
Active/Standby 
(ACT/STBY) 
Signal Fail (SF) 
 
Red 
Green/yellow 
 
Yellow 
 
Red 
Green/yellow 
 
Yellow 
 
Red 
Green/yellow 
 
Yellow 
 
Red 
Green/yellow 
 
Yellow 
Operating Environment  
Temperature 
–5 to 55°C 
23 to 131°F 
–5 to 55°C 
23 to 131°F 
–5 to 55°C 
23 to 131°F 
–5 to 55°C 
23 to 131°F 
Humidity 
5 to 95% RH 
5 to 95% RH 
5 to 95% RH 
5 to 95% RH 
Storage Environment  
Temperature 
–40 to 70°C  
–40 to 158°F 
–40 to 70°C  
–40 to 158°F 
–40 to 70°C  
–40 to 158°F 
–40 to 70°C  
–40 to 158°F 
Humidity 
5 to 95% RH 
 
5 to 95% RH 
 
5 to 95% RH 
 
5 to 95% RH 
Table 5. 
Optical Specifications for ROADM Cards  
Specification 
40-WSS-C/ 
40-WSS-CE 
40-DMX-C/ 
40-DMX-CE 
40-WXC-C 
40-MUX-C 
Optical Parameters 
Insertion Loss (maximum 
@ minimum VOA) 
 
7.5dB (EXP-RX – COM-TX) 
2.3dB (COM-RX – EXP-TX) 
6.8dB (Add 1-40 – COM-
TX) 
6.0dB (COM-RX – DROP-
TX) 
5.8 dB 
6.5 Max, 5.0 Typ 
5.8 dB 
Minimum VOA Dynamic 
Range 
20 dB (EXP-RX – COM-TX) 
25 dB (Add 1-40 – COM-
TX) 
25 dB 
20 dB 
25 dB 
Maximum Input Power 
25 dBm 
25 dBm 
25 dBm 
25 dBm 
Filter Type 
Array wave guide (AWG) 
Array wave guide 
(AWG) 
MEMS 
Array wave guide 
(AWG) 
Minimum Transmit Filter -1 
dB Bandwidth (all operating 
conditions and attenuation 
values) 
 
+/-135 pm (EXP-RX COM-
TX) 
 
+/-160 pm (Add COM-TX) 
+/-100 pm 
+/-110 pm  
+/-100 pm 
Adjacent Crosstalk 
(all operating conditions 
and attenuation values) 
 
23 dB (Minimum) 
 
30 dB (Typical) 
25 dB (Minimum)  30 dB (Minimum) 
 
25 dB (Minimum) 
Nonadjacent Crosstalk 
(all operating conditions 
and attenuation values) 
 
30 dB (Minimum) 
 
42 dB (Typical) 
34 dB (Minimum)  40 dB (Minimum) 
 
34 dB (Minimum) 
Maximum Polarization 
Dependent Loss (PDL) 
(all operating conditions 
and attenuation values) 
 
3.5 dB (Add 1-40 – COM-
TX) 
 
0.2 dB (COM-RX – EXP-
TX) 
 
0.4 dB (COM-RX – DROP-
TX) 
0.6 dB 
0.6 dB (5 to 10 dB Att. 
range) 
1 dB (15 to 20 dB Att. 
range) 
0.4 dB (COM-RX – DROP-
TX) 
0.6 dB 
Optical Power Setting 
Accuracy (all operating 
conditions and attenuation 
values) 
 
-0.7/0.7 dB 
±1.3dB (5 to 10 dB Att. 
range) 
±3.0dB (15 to 20 dB Att. 
range) 
 
Minimum Return Loss 
 
40 dB 
 
40 dB 
40 dB 
 
40 dB 
 
Connectors