Cisco 2RU 8-Degree Mesh Patch Panel 15454-PP-MESH-8= Scheda Tecnica
Codici prodotto
15454-PP-MESH-8=
Data Sheet
All contents are Copyright © 1992–2007 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information.
Page 7 of 9
Table 4.
ROADM Cards Specifications
Specification
40-WSS-C/
40-WSS-CE
40-WSS-CE
40-DMX-C/
40-DMX-CE
40-DMX-CE
40-WXC-C
40-MUX-C
Management
Card LEDs:
Failure (FAIL)
Active/Standby
(ACT/STBY)
(ACT/STBY)
Signal Fail (SF)
Red
Green/yellow
Yellow
Red
Green/yellow
Yellow
Red
Green/yellow
Yellow
Red
Green/yellow
Yellow
Operating Environment
Temperature
–5 to 55°C
23 to 131°F
–5 to 55°C
23 to 131°F
–5 to 55°C
23 to 131°F
–5 to 55°C
23 to 131°F
Humidity
5 to 95% RH
5 to 95% RH
5 to 95% RH
5 to 95% RH
Storage Environment
Temperature
–40 to 70°C
–40 to 158°F
–40 to 70°C
–40 to 158°F
–40 to 70°C
–40 to 158°F
–40 to 70°C
–40 to 158°F
Humidity
5 to 95% RH
5 to 95% RH
5 to 95% RH
5 to 95% RH
Table 5.
Optical Specifications for ROADM Cards
Specification
40-WSS-C/
40-WSS-CE
40-WSS-CE
40-DMX-C/
40-DMX-CE
40-DMX-CE
40-WXC-C
40-MUX-C
Optical Parameters
Insertion Loss (maximum
@ minimum VOA)
@ minimum VOA)
7.5dB (EXP-RX – COM-TX)
2.3dB (COM-RX – EXP-TX)
6.8dB (Add 1-40 – COM-
TX)
TX)
6.0dB (COM-RX – DROP-
TX)
TX)
5.8 dB
6.5 Max, 5.0 Typ
5.8 dB
Minimum VOA Dynamic
Range
Range
20 dB (EXP-RX – COM-TX)
25 dB (Add 1-40 – COM-
TX)
TX)
25 dB
20 dB
25 dB
Maximum Input Power
25 dBm
25 dBm
25 dBm
25 dBm
Filter Type
Array wave guide (AWG)
Array wave guide
(AWG)
(AWG)
MEMS
Array wave guide
(AWG)
(AWG)
Minimum Transmit Filter -1
dB Bandwidth (all operating
conditions and attenuation
values)
dB Bandwidth (all operating
conditions and attenuation
values)
+/-135 pm (EXP-RX COM-
TX)
TX)
+/-160 pm (Add COM-TX)
+/-100 pm
+/-110 pm
+/-100 pm
Adjacent Crosstalk
(all operating conditions
and attenuation values)
(all operating conditions
and attenuation values)
23 dB (Minimum)
30 dB (Typical)
25 dB (Minimum) 30 dB (Minimum)
25 dB (Minimum)
Nonadjacent Crosstalk
(all operating conditions
and attenuation values)
(all operating conditions
and attenuation values)
30 dB (Minimum)
42 dB (Typical)
34 dB (Minimum) 40 dB (Minimum)
34 dB (Minimum)
Maximum Polarization
Dependent Loss (PDL)
(all operating conditions
and attenuation values)
Dependent Loss (PDL)
(all operating conditions
and attenuation values)
3.5 dB (Add 1-40 – COM-
TX)
TX)
0.2 dB (COM-RX – EXP-
TX)
TX)
0.4 dB (COM-RX – DROP-
TX)
TX)
0.6 dB
0.6 dB (5 to 10 dB Att.
range)
range)
1 dB (15 to 20 dB Att.
range)
range)
0.4 dB (COM-RX – DROP-
TX)
TX)
0.6 dB
Optical Power Setting
Accuracy (all operating
conditions and attenuation
values)
Accuracy (all operating
conditions and attenuation
values)
-0.7/0.7 dB
-
±1.3dB (5 to 10 dB Att.
range)
range)
±3.0dB (15 to 20 dB Att.
range)
range)
-
Minimum Return Loss
40 dB
40 dB
40 dB
40 dB
Connectors