On Wednesday, normal operation begins at 7:30 and the unit goes into sleep mode at 22:00.
•  To wake the TeraStation from sleep mode manually, press the power button.
UPS (Uninterruptible Power Supply)
If a UPS (sold separately) is attached, the TeraStation can be automatically shut down for protecting data in the 
event of a power outage.
Plug the power cable of the UPS to a wall socket.
Connect the AC cable of the TeraStation to the UPS.
Connect the UPS and TeraStation using a USB cable.
Turn on the UPS, then the TeraStation.
In Settings, click Management.
Click 
 to the right of "UPS Sync".
Click Edit.
Configure the desired settings, then OK.
Notes: 
•  If the TeraStation is connected directly to a UPS, select "Sync with UPS connected to this TeraStation". If a 
different TeraStation is connected to the UPS, select "Sync with UPS connected to another LinkStation or 
TeraStation on the same network". After making this selection, enter the IP address of the TeraStation that will 
be the sync source in "Other LinkStation or TeraStation's IP Address".
•  When the TeraStation is rebooted after an automatic shutdown (such as from a power outage or power 
supply problem), verify that the power supply has been restored. If the TeraStation is turned on while it is 
still running on the UPS and without the power supply restored, automatic shutdown is not performed, even 
after the specified time has elapsed.
•  If the power supply from the UPS to the TeraStation is stopped and restarted when UPS recovery is enabled, 
the TeraStation is automatically restarted.