Chapter 10 Appendix
When the Power LED Blinks
No Color
The power LED will blink during bootup or shutdown.
Red
If there is an error, the power LED will blink red. For TS1200D models, the following blink patterns will give the error 
code. You can also see any errors in NAS Navigator2.
Place of Error Code
Status
10s Place of Error Code
The LED flashes for 1.0 second every 0.3 seconds. This gives the tens place 
of the error code.
1s Place of Error Code
The LED flashes for 0.5 seconds every 0.3 seconds. This gives the ones 
place of the error code.
Error Code
Description
Corrective Action
E10
The TeraStation is running on the UPS 
battery due to a power outage. The 
system will now be shut down safely.
Check that power is being supplied to 
the UPS, and if there are no problems, 
turn on the TeraStation.
E11
An error occurred in the fan speed.
Check the fan. Use compressed air or 
tweezers to remove any dust or foreign 
objects. Confirm that the fan is spinning 
normally. If it is not, contact Buffalo 
technical support for assistance.
E12
The system is overheating.
Do not place objects in the area 
around the TeraStation. Also, move the 
TeraStation to a cool location.
E13
An error occurred in the RAID array. The 
TeraStation is in degraded mode.
Replace the defective drive. Reboot the 
TeraStation and rebuild the RAID array.
E14
RAID array x cannot be mounted.
Run the RAID array disk check in 
Settings.
E15
The bad sectors have reached a 
dangerous level.
Replace the defective drive.
E16
Unable to find hard drive x.
Hard drive x may be disconnected 
or may have failed. Shut down the 
TeraStation and reinstall the hard drive.
E22
Mounting of hard drive x failed.
Format the hard drive. After formatting, 
if the error still appears after rebooting, 
replace the hard drive. If the error 
is displayed again, contact Buffalo 
technical support for assistance.