Buffalo 3TB LinkStation 410 LS410D0301 Manuale Utente

Codici prodotto
LS410D0301
Pagina di 173
LinkStation User Manual
168
Appendix
The Info/Error LED blinks red to indicate an error.  
The error may be identified by the pattern of blinking.  
Note:   The error may also be viewed from NAS Navigator2.
Error code
Descriptions
E00
MPU is abnormal; no power.  Contact Buffalo tech support for assistance.
E01
DRAM data line is abnormal.  Contact Buffalo tech support for assistance.
E02
DRAM address line is abnormal.   Contact Buffalo tech support for assistance.
E03
RTC chip is abnormal.   Contact Buffalo tech support for assistance.
E04
Kernel extraction failed. Contact Buffalo tech support for assistance. 
E14
The RAID array cannot be mounted. Turn off power, then turn power on again.  
If the same error is displayed, re-configure RAID.  And if the same error is displayed again, contact 
Buffalo tech support for assistance.
E15
Hard drive I/O error. Contact Buffalo tech support for assistance.
E16
The hard drive is not connected, or data transfer has failed. Check your hard drive status. If the error 
still remains, contact Buffalo tech support for assistance.
E17
Controller error.  Contact Buffalo tech support for assistance.
E21
Controller error.  Contact Buffalo tech support for assistance.
E23
The hard drive has crashed.  Contact Buffalo tech support for assistance.
Place
Status
10s place
The LED illuminates for 1 second every 0.3 seconds.
The number of flashes is the tens place of the error code.
1s place 
The LED illuminates for 0.5 seconds every 0.3 seconds.
The number of flashes is the ones place of the error code.
Power LED
Status
Descriptions
Solid Blue
The LinkStation is powered on.
Blinking blue
The LinkStation is starting up or shutting down.
Off
The LinkStation is off.