Buffalo TeraStation 3400r 12TB TS3400R1204-EU Scheda Tecnica

Codici prodotto
TS3400R1204-EU
Pagina di 179
137
from outside the local network (from the WAN side). To use this feature, connect the router to only LAN port 1 on 
the TeraStation.
UPS (Uninterruptible Power Supply)
If a UPS (sold separately) is attached, the TeraStation can be automatically shut down for protecting data in the event of 
a power outage.
Plug the power cable of the UPS to a wall socket.
Connect the AC cable of the TeraStation to the UPS.
Connect the UPS and TeraStation using a USB cable or serial cable.
Turn on the UPS, then the TeraStation.
In Settings, click Management.
Click 
 to the right of “UPS Sync”.
Click Edit.
Configure the desired settings, then OK.
Notes: 
•  If the TeraStation is connected directly to a UPS, select “Sync with UPS connected to this TeraStation”. If a differ-
ent TeraStation is connected to the UPS, select “Sync with UPS connected to another TeraStation on the same 
network.” After making this selection, enter the IP address of the TeraStation that will be the sync source in “Other 
TeraStation’s IP Address”.
•  When the TeraStation is rebooted after an automatic shutdown due to a power outage or other power supply 
problem, verify that the power supply has been restored. If the TeraStation is turned on while it is still running on 
the UPS and without the power supply restored, automatic shutdown is not performed, even after the specified 
time has elapsed.
•  If the power supply from the UPS to the TeraStation is stopped and restarted when UPS recovery is enabled, the 
TeraStation is automatically restarted.