Buffalo NAS server 8 TB TeraStation 5400 Rack WD Red TS5400RWR0804-EU TS5400RWR0804-EU Scheda Tecnica

Codici prodotto
TS5400RWR0804-EU
Pagina di 181
42
Click Set as a hot spare.
Step through the wizard.
When the “Confirm Operation” screen opens, enter the confirmation number and click OK.
Notes: 
•  To turn the hot spare back into a normal disk, choose Set as a normal disk.
•  If a drive fails in the RAID array before it is rebooted, the hot spare will not automatically replace the failed drive. 
In this case, follow the steps below to repair the array.
(1)  In Settings, navigate to Drives - Drives.
(2)  Select the drive that was configured as a hot spare, then click Dismount Disk.
(3)  Click Rediscover Disk.
(4)  Navigate to Drives - RAID.
(5)  Select the RAID array to repair.
(6)  Select the drive that was previously configured as a hot spare, then click “Recover RAID Array”.
This will rebuild the RAID array.
RMM (RAID Mode Manager)
With RMM, you can create or expand a RAID array without erasing the data on the drives.
Changing from JBOD to RAID 1
Hard drives that aren’t in a RAID array show “Normal (RMM available)”. You must have at least two drives available in 
JBOD (not in a RAID array) to build the RAID 1 array with RMM.
Click Drives.
Click RAID.
Choose a RAID array.