Automatic Link Restoration
Transition Networks's converters will automatically re-establish link in all network conditions.
Transition Networks's converters will automatically re-establish link when connected to switches if link was
lost. With other manufacturers' converters the user must reset the converter to re-establish the link.
Automatic Link Restoration allows the users to continue using Auto-Negotiation with Link Loss Notification
features. With other manufacturers' converters the user must disable Auto-Negotiation and hard set the link.
Automatic Link Restoration on Transition Networks's products allows users to continue using Link Loss
Notification feature activated in both directions. Many competitive solutions allow for Link Loss Notification
activation only in one direction. If Link Loss feature is activated in both directions, competitive products are
put in a "deadly embrace" and they cannot restore the link without resetting the converters.

No need to reset devices

Auto-Negotiation Enabled

Link Pass Through Activated in both directions
Advanced 
Product Features

Link Pass Through
Link Pass Through is a troubleshooting feature that prevents media converters from isolating link failures
and it allows end devices to be notified in the event of a loss of link. Link Pass Through provides the media
converter with the ability to monitor both the fiber and the copper RX ports for a loss of signal. If a loss of
RX signal occurs on one media port, the converter will automatically disable the TX signal on the other port.
By shutting down the fiber TX port, the link failure is “passed through” to the remote converter and device
(see diagram below).

End device automatically notified of link loss

Prevents loss of valuable data unknowingly transmitted over an invalid link