Arnold Rak 12 m Heating Cable / 30-6102 Scheda Tecnica

Codici prodotto
30-6102
Pagina di 9
 
 
 
Installation 
Instructions 
 
 
Heating Cable TWIN Series 61 
Flexible Installation In Complex Room Shapes  
 
 
Product Information 
 
The  TWIN  series  heating  cables  are  supplied  ready  for  connection,  including  a  3  m  long  connection  cable 
(cold conductor). They are available with a rated power of 30 W per meter. 
The  cables  are  manufactured  to  VDE  standards  DIN  EN60335-2-96,  DIN  EN60335-1,  and  DIN  EN  50366. 
Approval: VDE (heating conductor). 
The application areas detailed below are indoor floor temperature control and outdoor surface heating. 
 
 
Type 
Voltage 
Power 
Diameter 
Rated 
temperatur 
limit 
Connection 
cable 
Insulation 
Minimum 
Installation 
spacing 
61xx-30 
230 V 
30 W / lfm 
5 mm 
80° C 
3x1,0 mm
2
 
FEP(Teflon®) / 
Polyester / PVC 
9 cm 
 
 
Heating Cable Type 61xx-30, 30 W / rm, 5 mm 
for indoor floor temperature control and outdoor surface heating 
 
This heating cable can be embedded directly into the screed (min. 20 mm screed above the heating cable) 
and  is  therefore  especially  suited  for  newly  built  properties  in  which  the  flooring  has  not  been  finished  yet. 
Depending on individual requirements, the heating performance range is 150 to 350 W/m
2
. For tiled floors up 
to 200 W/m
2
 can be used and for other flooring materials such as parquet, laminate, carpet or linoleum 160 
W/m
2
 should not be exceeded. 
The heating cable is also used for outdoor surface heating, for example, for heating external stairs, entrance 
areas,  patios  and  driveways  and  for  keeping  them  free  of  snow  when  required.  Use  as  a  roof  or  gutter 
heating system is also possible. 
The cable is not intended for embedding in bituminous mastic or reinforced concrete. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
GB