MEAN WELL CLG-100-24 Scheda Tecnica

Pagina di 3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
IP67
..
SPECIFICATION
MODEL
CLG-100-12
CLG-100-15
CLG-100-20
CLG-100-24
CLG-100-27
CLG-100-36
CLG-100-48
DC VOLTAGE
RATED CURRENT           
Note.5
RATED POWER               
Note.5
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION      
LOAD REGULATION      
 
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE          
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(
)
Typ.
LEAKAGE CURRENT
SAFETY STANDARDS    
Note.8
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT (Typ.)    
OVER VOLTAGE           
 
OVER TEMPERATURE
12V
9 ~ 12V
15V
11.25 ~ 15V
20V
15 ~ 20V
24V
18 ~ 24V
27V
20.25 ~ 27V
36V
27 ~ 36V
48V
36 ~ 48V
5A
5A
4.8A
4A
3.55A
2.65A
2A
60W
75W
96W
96W
95.85W
95.4W
96W
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
±3.0%
±3.0%
±3.0%
±3.0%
±3.0%
±2.0%
±2.0%
Fixed. Can be modified between 0% ~ -15% rated output voltage
Fixed. Can be modified between 3% ~ -25% rated output current
±1.0%
±2.0%
500ms, 80ms / 230VAC          
 at full load
1200ms, 80ms / 115VAC
60ms / 230VAC          30
 at full load
ms / 115VAC
90 ~ 295VAC          127 ~ 417VDC
47 ~ 63Hz
PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
30 ~ 36V
39 ~ 48V
52 ~ 64V
COLD START 40A(twidth=1030 s measured at 50% Ipeak) at 230VAC
μ
<0.75mA / 240VAC
95 ~ 102%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV),  criteria A
-30 ~ +70
 
℃ (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.03%/
 (0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for  72min. each along X, Y, Z axes
301Khrs min.      MIL-HDBK-217F (25
)
222.2*68*38.8mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement 
    of UL1310 class 2.
6. 3 years warranty is guaranteed for operating ambient temperature no higher than 68℃.
8. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the 
    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Please refer to "DRIVING METHODS OF LED MODULE".
10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently 
      connected to the mains.
1.0Kg; 12pcs/13Kg/0.58CUFT
Protection type : Shut down and latch off o/p voltage, re-power on to recover
100W Single Output Switching Power Supply
Universal AC input / Full range (up to 295VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature 
Cooling by free air convection
IP67 design for indoor or outdoor installations
Class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting 
Suitable for dry / damp / wet locations
3 years warranty (Note.6)
High efficiency up to 88.5%
 Features :
C L G - 1 0 0  
s e r i e s
RIPPLE & NOISE (max.)  
Note.2
VOLTAGE TOLERANCE  
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
( for 48V only)
( except for 48V )
F
M
M
110
LPS
SELV
CONSTANT CURRENT REGION 
Note.7
SHORT CIRCUIT              
 
Hiccup mode, recovers automatically after fault condition is removed
File Name:CLG-100-SPEC   2014-03-26
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (≧75% load) ; EN61000-3-3
EMC IMMUNITY
EMC EMISSION
83%
85%
88.5%
88.5%
88%
88%
88.5%
12V:0.8A/115VAC     0.4A/230VAC
          
    0.3A/277VAC
15V:0.9A/115VAC     0.45A/230VAC    0.35A/277VAC
20V ~ 48V:1.1A/115VAC     0.55A/230VAC     0.45A/277VAC
CSA C22.2 No. 250.0-08(except for 48V), CSA C22.2 No. 207-M89(except for 48V), TUV EN60950-1, IP67, J61347-1, J61347-2-13  approved
UL879, UL8750, UL1310, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V),