Idec Safety button 250 Vac 3 A Steel lever (straight), Steel lever (curved) momentary HS6B-11B01-SET IP67 1 pc(s) HS6B-11B01-SET Scheda Tecnica

Codici prodotto
HS6B-11B01-SET
Pagina di 5
16
HS6B
 Subminiature Interlock Switches
World-class compactness with three poles of contacts.
• Vertical/horizontal Angle 
Adjustable Actuator (for 
hinged door)
• Right-angle Actuator
(SUS
3
04)
• Straight Actuator 
(SUS
3
04)
• World’s smallest switch: 
3
×
 
3
×
 7
8
 mm
• Dual contacts and monitor contacts achieve the highest safety 
category (ISO 1
38
49-1, EN 954-1)
• Two actuator entry slots provide flexibility for installation options.
• Integral cable design minimizes wiring, preventing wiring 
mistakes.
• Can be mounted in two directions.
• Degree of protection (contacts): IP67 (IEC 60529)
Housing allows drainage.
• NC contacts are direct opening action (IEC/EN 60947-5-1).
• Proprietary actuators prevent unauthorized opening of the 
contacts (ISO14119, EN10
88
).
Do
ub
le
In
su
l
a
tion
Direct
Opening
Action
Types
Actuators
Note: Select an actuator that moves in the direction required by the 
hinged door and interlock switch (see pages 17 and 1
8
).
Contact Ratings
• Minimum applicable load (reference): 
3
V AC/DC, 5mA
Ratings approved by safety agencies
C
3
00: AC-15, 0.75A/240V
Q
3
00: DC-1
3
, 0.27A/250V
Specifications
Contact Configuration Cable Length
Type No.
(Package quantity: 1)
1NC-1NO
1m
HS6B-11B01
3
m
HS6B-11B0
3
5m
HS6B-11B05
2NC
1m
HS6B-02B01
3
m
HS6B-02B0
3
5m
HS6B-02B05
2NC-1NO
1m
HS6B-12B01
3
m
HS6B-12B0
3
5m
HS6B-12B05
3
NC
1m
HS6B-0
3
B01
3
m
HS6B-0
3
B0
3
5m
HS6B-0
3
B05
Description
Type No.
(Package quantity: 1)
Straight
HS9Z-A61
Right-angle
HS9Z-A62
Horizontal/vertical Angle Adjustable
(for hinged doors) (Note)
HS9Z-A65
HS9Z-A66
Rated Insulation Voltage (Ui)
3
00V
Rated Current (Ith)
2.5A
Rated Voltage (Ue) 
3
0V
125V
250V
Rated
Current 
(Ie) 
AC
Resistive load (AC-12)
2.5A
1.5A
Inductive Load (AC-15)
1.5A
0.75A
DC
Resistive load (DC-12)
2.5A
1.1A
0.55A
Inductive Load (DC-1
3
)
2.
3
A
0.55A
0.27A
34
33
12
Z
b
11
32
31
11
Z
b
12
32
31
12
22
Z
b
11
21
31
21
11
Z
b
32
22
12
Applicable Standards
UL50
8
 (UL listed)
CSA C22.2, No. 14 (c-UL listed)
ISO 14119
EN 10
88
IEC 60947-5-1
EN 60947-5-1 (DEMKO approval)
GS-ET-15 (BG approval)
IEC 60204-1/ EN 60204-1
(applicable standards for use)
Applicable Directive
7
3
/2
3
/EEC (Low Voltage Directive)
Operating
Temperature
–25 to +70°C (no freezing)
Relative Humidity
45 to 
8
5
%
 (no condensation)
Storage Temperature
–40 to +
8
0°C (no freezing)
Pollution Degree
3
Impulse Withstand 
Voltage
4 kV
Insulation Resistance 
(500V DC megger)
Between live and dead metal parts:
100 M
Ω 
minimum
Between terminals of different poles:
100 M
Ω 
minimum
Contact Resistance
3
00 m
Ω
 maximum (initial value, 1m cable)
500 m
Ω
 maximum (initial value, 
3
m cable)
700 m
Ω
 maximum (initial value, 5m cable)
Electric Shock
Protection Class
Class II (IEC 61140)
Degree of Protection
IP67 (IEC 60529)
Shock Resistance
Operating extremes:
3
00 m/s
(
3
0G)
Damage limits:
1000 m/s
(100G)
Vibration Resistance
Operating extremes:
5 to 55 Hz, amplitude 0.5 mm
Damage limits:
3
0 Hz, amplitude 1.5 mm
Actuator Operating 
Speed
0.05 to 1.0 m/s
Direct Opening Travel
8
 mm minimum
Direct Opening Force
60N minimum
Operating Frequency
1200 operations/h
Mechanical Durability
1,000,000 operations minimum (GS-ET-15)
Electrical Durability
100,000 operations minimum 
(operating frequency 1200 operations/h,
load AC-12 250V/1.5A, DC-12 250V/0.2A)
Conditional
Short-circuit Current
50A (250V) (Use 250V/10A fast-blow fuse for short- 
circuit protection.)
Housing Color
Black
Cable
UL2464 No. 20 AWG (6-core)
Weight (approx.)
120g (HS6B-0
3
B01)
(07/03/16)