TE Connectivity SOLARLOK Blue Content: 1 pc(s) 7-1579010-4 Manuale Utente

Codici prodotto
7-1579010-4
Pagina di 12
 
Application Specification                   114-106078 
Jul 11
th
, 2013   Rev. C1 
This specification is a controlled document.                                      Page 6 of 12 
 
© Copyright 2012 by TE Connectivity Corporation 
All rights reserved 
B. Effective Crimp Length 
For optimum crimp effectiveness, the crimp must be within the area shown in Figure 4 and 
must meet the crimp dimensions provided in Table 2
C. Wire-End Protrusion Length 
The wire barrel shall not exceed the dimension shown in Figure 4 and Table 2.  
D. Wire Location 
The wire conductor must be visible in the transition area between the wire barrel and 
insulation as shown in Figure 4
E. Wire Barrel Seam 
The wire barrel seam must be closed with no evidence of loose wire strands visible in the 
seam. See Figure 4
3.2.3  Crimping Tooling 
Because of the large amount of product variations and application tooling available, it is not 
feasible to list all the tooling on this document. The operation instructions packaged with that 
tooling. The following tools are available for the contact crimping 
 
3.2.3.1  Hand  Crimping Tool 
Hand crimping tools are designed for low-volume application and repair. 
 
No. 
TE connectivity  
Part Number 
Wire size 
Approval 
Order Text 
Picture 
4-1579002-2 
2.5 +4.0+6.0mm
2
 
N/A 
SOLARLOK insulation 
stripper 
 
6-1579014-8 
4.0+6.0mm
2
 
N/A 
Hand-crimp tool (complete) 
for crimping contact 
 
4-1579016-7 
4.0+6.0mm
2
 
N/A 
Crimp head for crimping 
contact 
 
Table 3 
The PV4 contact crimping should be done using the TE preferred crimp tool, (PN 
6-1579014-8).  Other manufacturer crimp tools may be able to be used to crimp 
the PV4 contact, but users should first check with their local TE sales engineer for 
the current listing of other manufacturer's compatible tools. 
3.2.3.2  Applicators 
Applicators are designed for the full wire size range of terminals, and provide for high volume or 
mass production requirements. The applicators can be used in bench or floor model power units. 
Each applicator is shipped with a metal identification tag attached. Do not remove this 
tag or disregard the information on it. Also, a packet of associated paperwork is 
included in each applicator shipment. This information should be read before using the 
applicator; then it should be store in a clean, dry area near the applicators for future 
reference. Some changes may have to be made to the applicators to run in all related 
power units. Contact TE connectivity corporate engineering.