Application Specification                   114-106078 
Jul 11
th
, 2013   Rev. C1 
This specification is a controlled document.                                      Page 9 of 12 
 
© Copyright 2012 by TE Connectivity Corporation 
All rights reserved 
3.4  Connectors Mating 
When mating the connectors, ensure the following; 
  It is only allowed to connect a plus (+) coded connector to a minus (-) coded connector. 
Connectors with identical polarity mark are not allowed to couple (forbidden to use + on + or - 
on -
  Mating of the connectors is done by pushing the connectors together until a clear audible 
click is heard. This clear audible clicking sound must be heard to ensure the connectors have 
been mated correctly. When the connectors are correctly connected the latches should be 
flush against the edge of the connector (see Figure 10). 
 
Figure 10 
The  polarity symble + or 
– are marked on the Connector (See Figure 11) 
 
 
Figure 11 
3.5  Disconnecting 
Do NOT disconnect under load! 
Current path should only be disconnected using approved disconnect devices. 
 
 
The following hand application tool (PN 1971903-1) is available for assembling and disconnecting 
the connector in Figure 12, and tightening the cable screw joint nut for low-volume application 
and repair.