Keba 86.875 Electric Cars KEBA 86.875 Electric Cars N/A Silver, Grey Silver, Grey 86.875 Scheda Tecnica

Codici prodotto
86.875
Pagina di 48
Installation
 KeContact 
P20 
28 
Installation
 manual, Version: 1.41 / Article no.: 90064 
 
© KEBA 2012-2013 
4.4.3  Enable input [X1] 
The enable input is equipped for the use with a potential-free contact. Using the enable input, 
it is possible to control the charging station using external components (e.g. external key 
switches, ripple control receiver of the energy supplier, house control, time switches, combi-
nation lock, photovoltaic system etc.). 
 
Circuit diagram: 
 
 
 
Electrical requirements: 
Ensure a safe separation from dangerous voltages for this control cable outside of the de-
vice. 
 
 
Logical function: 
 
Enable contact 
State of the charging station 
Open 
LOCKED 
Closed 
READY FOR OPERATION 
 
 
Connection: 
► 
Connect the wires to the enable input (please refer to the "Terminals [X1/X2]" chapter 
for details about the terminal). 
 
 
 
DIP-switch setting 
DIP-switch setting 
The use of the enable input must be activated 
by a DIP-switch setting. 
 
Using the enable input: 
 
- "Yes":  
DSW1.1 = ON 
- "No":   
DSW1.1 = OFF (Default)