KeContact P20 
Important information
 
Installation
 manual, Version: 1.41 / Article no.: 90064 
© KEBA 2012-2013 
 
1 Important 
information 
1.1  Safety instructions 
 
!
 
 
 
WARNING! 
 
Not observing the safety instructions can result in risk of death, injuries and dam-
age to the device! KEBA AG assumes no liability for claims resulting from this! 
 
 
Electrical hazard! 
The installation, commissioning and maintenance of the charging station may 
only be performed by correctly trained, qualified and authorized electricians 
who are fully responsible for the compliance with existing standards and in-
stallation regulations. 
 
Please observe that an additional overvoltage protection of vehicles or national 
regulations can be required. 
 
Also observe that some countries or vehicle manufacturers may require a dif-
ferent triggering characteristic of the fault-current circuit breaker (Type B). 
 
Only connect voltages and circuits in the right-hand connection area (Ethernet, 
terminals for control lines) that have a secure separation to dangerous volt-
ages (e.g. sufficient isolation). 
 
Only supply the terminals (X2) from voltage sources which feature safety extra-
low voltage! 
 
Before commissioning, check all screw and terminal connections for firm seat-
ing! 
 
The connector panel cover may never be left open unattended. Mount the con-
nector panel cover if you leave the charging station. 
 
Do not carry out any unauthorized conversion work or modifications to the 
charging station! 
 
Repair work to the charging station is not permitted and may only be per-
formed by the manufacturer (replacement of the charging station)! 
 
Do not remove any notices on the device, such as safety symbols, warning 
notices, rating plates, nameplates or cable markings! 
 
The charging station does not have its own power switch! The RCD circuit 
breaker and the line circuit breaker of the building installation serve as mains 
disconnector. 
 
Observe the instructions given for selecting the location and the construc-
tional requirements! 
If the specifications for the location are not observed, this can result in death, 
serious physical injury or equipment damage if the corresponding precaution-
ary measures are not met!