5. Troubleshooting 
5.1 Wind Turbine Troubleshooting 
 
5.1.1 Wind Turbine Vibration 
Wind turbine vibration is mainly caused by the following factors: 
1) The blades mounting bolts get loose and need to be tightened; 
2) The surface of blades gets frozen and needs to be removed; 
      3) The blades have been distorted, defected and need to be replaced. 
4) The tower is not strong enough or guy rope gets loose, and needs to be reinforced or tightened; 
5) The wind turbine operates lacking phase, need to check if the three-phase output voltage is balanced or not by testing with multimeter. 
 
IMPORTANT: Turbine operation should be stopped as soon as abnormal vibration happened till problems solved to avoid personnel or machine damaged. 
 
 