Safety Instructions 
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ASSEMBLING, INSTALLATING OR OPERATING OF YOUR HY WIND TURBINE. 
1. Before HY series small wind turbine installation, you must know: 
1) Do not install wind turbine on a windy day or dusty day with wind speed more than 8m/s.   
2) Wearing wet gloves or clothes are forbidden.   
3) Installing or maintaining wind turbine must be under professionals’ guidance or contacting distributors.   
4) Please Using cables as the standard mentioned in this user manual section 4 (wire size selection), cables too thin or with poor quality may lead to leakage or fires and line losses.   
5) Non-professionals do not open the controller and inverter enclosure, any warranty claim will not be accepted if controller or inverter opened unauthorized.   
6) Grounding device installation must be in accordance with application standard and installation instruction. 
7) Battery wiring may splash spark, please makes sure without any inflammables near the work environment. 
8) Please do not place the controller, inverter and battery at damp, rain, vibration, corrosion and strong electromagnetic interference environment, the places in direct sunlight, near heater 
or other heat sources are not allowed either. 
 
2. Selection and installation requirements of controller and inverter: 
1) Controller specification should be accordance with voltage, power, current of battery, solar panel battery set, and wind turbine and laden. 
2) It is appropriated to install controller and battery in the same distribution box, and place it at a drafty room out of people reaching. Take some methods to prevent children from entering 
or stretching out hands into box. 
3) Controller and battery installation should be accordance with relevant electrical equipment installation specification and comply with the operation specification constituted by 
manufacturer. 
4) It is appropriated to use sealed lead acid battery for distribution box at inhabited room. 
 
3. Wiring requirements: 
1) The hardwired connect between components in system should be fixed and reliable.    Do not use plugs or sockets. 
2) Connect between system output terminal and external circuit
 
should be fixed, or use socket for system output terminal. 
3) Do not use two-way plug adapter for the connection of system’s output terminal with external circuit. 
4) Apart from the installation of the permanent circuit, any cables or wires that might be damaged due to outdoor exposure should be sheathed with conduit for protection.