Flashes orange slowly
every 5 seconds
Temperature limit exceeded (charging procedure temporarily interrupted;
charging continues after cooling down)
charging continues after cooling down)
Flashes red
Malfunction (for details, see "Troubleshooting")
Segment 1 lights up
orange
RFID programming mode (RFID cards can be programmed in this mode.
For details, see "Programming RFID user cards")
For details, see "Programming RFID user cards")
Segment 2 lights up
orange
Commissioning mode
(the charging station is in commissioning mode)
(the charging station is in commissioning mode)
3.4 Authorization (optional)
An (optional) authorization of a user for charging at the charging station can either
occur with a key switch or by means of RFID user cards depending on the de-
vice version.
Authorization required:
The status LED flashes blue slowly every 3 seconds.
occur with a key switch or by means of RFID user cards depending on the de-
vice version.
Authorization required:
The status LED flashes blue slowly every 3 seconds.
Authorization successful:
A successful authorization will be indicated by a series of increasing tones.
Authorization failed:
A failed authorization will be indicated by a series of decreasing tones.
Note
After successful authorization, if the charging procedure is not started within 60 seconds, the
automatic enable expires.
After successful authorization, if the charging procedure is not started within 60 seconds, the
automatic enable expires.