Arnold Rak 30 m Heating Cable / Set 6105-15 Scheda Tecnica

Codici prodotto
Set 6105-15
Pagina di 11
Installation
Instructions
Heating Cable TWIN Series 61
Flexible Installation In Complex Room Shapes
Product Information
The  TWIN  series  heating  cables  are  supplied  ready  for  connection,  including  a  3  m  long  connection  cable 
(cold conductor). They are available with a rated power of 15 W and 20 W per metre.
The  cables  are  manufactured  to  VDE  standards  DIN  EN60335-2-96,  DIN  EN60335-1,  and  DIN  EN  50366. 
Approval: VDE (heating conductor).
The application areas detailed below are indoor floor temperature control and outdoor surface heating.
Type
Voltage
Power
Diameter
Rated 
temperature 
limit
Connection 
cable
Insulation
Minimum 
installation 
spacing
61xx-15
230 V
15 W / rm
3 mm
80° C
3x1.0 mm
2
FEP(Teflon®) /
Polyester / PVC
5 cm
61xx-20
230 V
20 W / rm
5 mm
80° C
3x1.0 mm
2
FEP(Teflon®) /
Polyester / PVC
6 cm
Heating Cable Type 61xx-15, 15 W / rm, 3 mm
for indoor floor temperature control 
This  is  used  everywhere  a  heating  matt  cannot  be  used  due  to  unconventional  room  shapes,  e.g.  niches, 
corners, gaps, steps, pedestals, narrow passages, semicircular rooms and similar places. Because of its low 
profile, the heating cable is particularly suited for modernisation projects as well as newly built houses, where 
it  can  be  installed  immediately  below  floor  coverings.  Depending  on  individual  requirements,  the  heating 
performance  range  is  90  to  220  W/m
2
.  For  tiled  floors  up  to  200  W/m
2
  can  be  used.  For  other  flooring 
materials such as parquet, laminate, carpet or linoleum 160 W/m
2
 should not be exceeded.
Please always ensure that the chosen flooring material is suitable for under-floor heating.
Heating Cable Type 61xx-20, 20 W / rm, 5 mm
for indoor floor temperature control and outdoor surface heating
This heating cable can be embedded directly into the screed (min. 20 mm screed above the heating cable) 
and  is  therefore  especially  suited  for  newly  built  properties  in  which  the  flooring  has  not  been  finished  yet. 
Depending on individual requirements, the heating performance range is 140 to 350 W/m
2
. For tiled floors up 
to 200 W/m
2
 can be used and for other flooring materials such as parquet, laminate, carpet or linoleum 160 
W/m
2
 should not be exceeded.
The heating cable is also used for outdoor surface heating, for example, for heating external stairs, entrance 
areas,  patios  and  driveways  and  for  keeping  them  free  of  snow  when  required.  Use  as  a  roof  or  gutter 
heating system is also possible.
The cable is not intended for embedding in bituminous mastic or reinforced concrete.
GB