Mueller DIN rail mount timer digital Müller SC 88.20 pro 230 Vac 10 A/250 V SC 88.20 pro Scheda Tecnica

Codici prodotto
SC 88.20 pro
Pagina di 2
 
                   BA SC2819-SC88-SC98-pro MP; DE, GB - 22476 - 2008.05-03 
Instruction Manual
 (Site 1/2)
GB
Time switch (weekly or yearly program)
 SC 28.19 pro / SC 88.X0 pro / SC 98.X0 pro     
172 419 pro / 179 4X0 pro / 179 6X0 pro
Connection diagram 
Directory 
1. Safety instructions 
35mm (1 channel) 
Yearly time switch 
70mm (1 channel - 4 channels) 
Weekly or yearly time switch 
1  channel = Connection A 
2  channels =  Connection A,B 
3  channels =  Connection A,B,C 
4  channels =  Connection A,B,C,D
1. Safety instructions 
2. Initial operation 
3. DCF (Installation DCF-receiver) 
4. Menu overview 
5. Symbol legend 
6. Key function 
7. Handling advice 
8. Channel 
ON  OFF / Permanent P
9. Programming menu 
10. Standard weekly program 
11. Example of a standard weekly  
      switching time 
12. Cycle 
13. Cycle options
14.  Pulse 
15. Priority of the switching programs 
16. Special program entry 
17. Special program activation 
18. Extra switching time 
19. Permanentprogram 
20. External Input   
21. Switchoff warning 
22. Channel keys 
23. Additional adjustments 
24. Program modify 
25. Data-key 
!
The installation and assembly of electrical equipment must be only carried out only 
by a skilled Person! Otherwise fire danger or danger of an electric shock exists! 
!
Connect the supply voltage/frequency as stated on the product label! 
!
Warranty void if housing opened by unauthorised person!
!
The electronic circuit is protected against a wide range of external influences. 
Incorrect operating may occur if external influences exceed certain limits! 
2.  Initial operation 
3. DCF (Installation of the DCF-antenna FU 20) 
ƒ
The time switch is delivered in sleep-mode, the display is switched off. 
ƒ
Press 
-button for 1 second. 
ƒ
The current date and time is already programmed and European 
daylight savings time is activated. 
ƒ
Select the desired language by pressing 
-buttons and confirm it by 
pressing 
(Remark: By pressing 
 you move one step backwards 
from the current position)
ƒ
If required, date, time and daylight savings time mode can be adjusted 
also by pressing 
-buttons and a subsequent confirmation with 
.
The time switch can process the DCF signal.
The antenna FU 20 is not included in delivery of the time switch. 
ƒ
Disconnect power supply voltage 
ƒ
Connect the antenna as indicated by the connection diagram 
ƒ
Connect supply voltage 
ƒ
Antenna symbol (LCD) flashes for approx. 3 minutes 
Reception is not possible if severe interference is present 
(Permanent flashing of the symbol / The oscillating crystal is used as time base) 
Defective wire between antenna and time switch 
(No antenna symbol visible / The oscillating crystal is used as time base)
4.  Menu overview 
5.  Symbol legend 
Channel is switched ON 
Channel is switched OFF 
For the current date the “holiday program” / “permanent by date” is activated 
Standard programming step 
Current state is based on a manual over-ride. The state will be cancelled with the next 
programming step 
Current state is based on a manual over-ride. The state is permanent until terminated manually 
Days of the week Monday, Tuesday, ... Sunday;  
The underscores indicate if the program is active for the days above 
I
Current state is based on a switching time with pulse function  
Z
Current state is based on a switching time with cycle function 
W
Weekday function: Switching time is entered by date but is shifted for future years in respect of 
the weekday (E.g. Tuesday this year... Tuesday next year). 
e
Is displayed if the corresponding channel is activated by the external input. 
6.  Key function 
Element within sub-menu “program delete” 
1. To access the Enter-mode (program, adjustments, options) from the automatic-mode. 
2. To revert to the beginning of the current (sub-) menu.   
F
Switching function / switching time with Easter function: The switching function takes into account 
the yearly shift of Easter holiday for future years and changes the date of the switching program 
accordingly.
1. To adjust the flashing digit. 
2. To scroll through a choice 
X
1x-Function active: The switching time will be executed only once. 
1. Automatic-mode: To switch the channel ON or OFF until the next programming step occurs. 
2. Automatic-mode: A push longer than 3 sec. = Permanent switching status (7). 
D
DCF: The time switch receives the signal for the DCF -77 time standard  
1. To activate the time switch when operated without power supply. 
2. To confirm the selection or the entered data. 
The time switch is locked; to unlock the device the PIN has to be entered 
7. Handling advice 
8. Channel ON OFF / Permanent P
9. Programming menu 
ƒ
The time switch is programmable without external power supply 
after pressing the 
 -button. 
ƒ
To revert one step or one level back while in the Enter-Mode press
.
ƒ
After completion of a (sub-) menu confirming 
end
 will return the 
device into the automatic-mode. 
ƒ
With 
 the choice changes from 
end
 to 
continue
. By 
confirming 
continue
 the time switch returns to the beginning of 
the current (sub-) menu. 
ƒ
When confirming 
end
 before completion, the time switch returns 
to the automatic-mode without saving the entered data. 
Channel 
ON OFF
By pushing 
-buttons a manual switch of the channels 
take place. The resulting switching status is marked with 
the hand-symbol and remains until the next programming 
step occurs. (temporary over-ride) 
Permanent switching status 
P
By pressing the corresponding channel button 
for 
more than 3 sec. the channel is permanently switched ON 
or OFF. The status remains until the next manual switching 
occurs (> 3 sec.). (permanent over-ride) 
*within yearly time switches 
10. Standard weekly program 
11. Example for the programming of STANDARD switching times (ON and OFF)
**The cycle function will only be available if it is activated (point 13) 
A. If you want to program a standard weekly switching time (
on
,
off
) confirm 
Standard
 with  .
B. For regular switching times choose 
on
 or 
off
 with 
-buttons and confirm with  .
C. Within this level you activate the days of the week (1…7) on which the switching time should happen. 
With 
 you activate “yes” or deactivate “no” the corresponding date. Confirm each day with 
.
D. Adjustment of the time: Hours 
 and
. Minutes 
 and
.
E. Verify the entered switching time: If the flashing summary of the programming step is correct, verify 
on
or 
off
 with 
. After verification you have the choice between 
edit/delete
 and 
end
 with 
.
F. If you want to proceed with programming, confirm 
next switching
with 
.
To leave the programming menu confirm 
end
.
Information: You can easily transfer switching times from one channel to the other if you use the 
copy function. 
12. Cycle 
13. Cycle options 
Standard weekly program:
Program
 -> new program -> channel A/B/C/D -> Standard ->  …
Special (weekly) program (to be activated by date for the yearly function):
Program
 -> new program -> channel A/B/C/D -> Special-program ->  SP-entry -> program-number ->  …
For the cycle function it is possibile to enter a periodic switching time. The time switch acts as a recycling timer and 
switches between pulse (ON) and pause (OFF). The max. value for pulse and pause is 9:59:59 h:mm:ss.  
If you haven’t defined and activated a cycle, the cycle function will not be available as switching time. Therefore you 
have to activate and define at least one of the four cycles within menu 
Options
 and sub-menu 
Cycle
 (point 13). 
The cycle switching time will be terminated by another switching time (
on
,
off
,
pulse
) or by another cycle switching 
time. 
Options
 -> Cycle -> Cycle 1 - 4 -> …
You have the possibility to define 4 different Cycles. For these purposes choose menu 
Options
 and sub-menu 
Cycle
. The different 
cycles can be activated, defined or deactivated (the max. value for pulse or pause is 9:59:59 h:mm:ss): 
ƒ
Choose menu 
Options
 and sub-menu 
Cycle
 and confirm with  
.
ƒ
Select with 
 -buttons one out of the 4 cycles (
Cycle 1 – Cycle 4
) and confirm with  .
ƒ
Activate the cycle by changing 
No
 to 
Yes
 with 
  -buttons and subsequent confirming with 
.
ƒ
Define duration of the pulse 
„on-time“
 (
 ->  …). 
ƒ
Define duration of the pause 
„off time“
 (
 ->  …). 
ƒ
Confirm 
End
 with 
.
The cycle is now offered within the programming menu.  
Further applications of the cycle function in combination with: External Input function and/or Channel keys function. 
14. Pulse 
15. Priorities of the switching programs 
Standard weekly program:
Program
 -> new program  -> channel A/B/C/D -> Standard ->  …
Special (weekly) program (to be activated by date for the yearly function):
Program
 -> new program  -> channel A/B/C/D -> Special-program ->  SP-entry -> program-number ->  …
The pulse function provides you the opportunity of programming a switching time with a defined duration. 
As soon as the pulse-duration has expired the time switch switches OFF automatically (the duration of the pulse is up to 
59:59 mm:ss). 
Standard switching times, Special programs, Extra switching times and Permanent by date are executed according to their 
corresponding priority (by channel and date)  
All switching programs except Extra switching times, suspend all other switching programs with lower priority: 
 highest 
priority 
   
Ö  manual 
over-ride 
Permanent (3 sec. push)  
                 
× 
 
 
 
Ö
Permanent by date
                 
× 
 
 
 
Ö   
 
Extra switching time    
 
(yearly time switch)
         
× 
 
 
 
Ö   
 
Special program 10 by date   (yearly time switch)
        
× 
 
 
 
Ö   
 
Special program ... by date    (yearly time switch)
        
× 
 
 
 
Ö   
 
Special program 01 by date   (yearly time switch)
 lowest 
priority 
   
Ö
Standard weekly program