Baco BACO N/A 33E10Y7 1 x Off/On Screw terminals Max 10 A 33E10Y7 1 x Off/On Screw terminals Max 10 A B33E10Y7 Scheda Tecnica
Codici prodotto
B33E10Y7
7 / 9
R
R
R
Reeeeffffeeeerence(s)
rence(s)
rence(s)
rence(s) : : : : See
See
See
See range
range
range
range sec
sec
sec
section
tion
tion
tion
4.
4.
4.
4. INSTALLATION
INSTALLATION
INSTALLATION
INSTALLATION
Control station mounting
Control station mounting
Control station mounting
Control station mounting ::::
. use base mounting contact blocks
Printed circuit board mounting
Printed circuit board mounting
Printed circuit board mounting
Printed circuit board mounting ::::
. use Pin-style contact blocks
Current
Current
Current
Current ssssupply
upply
upply
upply ::::
. On the back side of the block
Visualization of the contact state
Visualization of the contact state
Visualization of the contact state
Visualization of the contact state::::
. Contact state is visible on the back side of the contact block,
mounted block (colour plunger, visible)
mounted block (colour plunger, visible)
Type
Type
Type
Type of
of
of
of wire
wire
wire
wire ::::
For screw terminal contact blocks (front mounting or base
mounting):
. Solid or stranded wire without ferrule : 2x 0,5 mm² to 2x 2,5
mm²
. Solid or stranded wire with ferrule : 2 x 0,5 mm² to 2 x 1,5 mm²
For plug-in terminal contact blocks:
mounting):
. Solid or stranded wire without ferrule : 2x 0,5 mm² to 2x 2,5
mm²
. Solid or stranded wire with ferrule : 2 x 0,5 mm² to 2 x 1,5 mm²
For plug-in terminal contact blocks:
. Solid or stranded wire without ferrule : 2x 0,5 mm² to 2x 2,5
mm²
. Solid or stranded wire with ferrule : 2 x 0,5 mm² to 2 x 1,5 mm²
For Faston terminal contact blocks :
. 1 faston clip 6,35 mm or 2 faston clips 2,85 mm
For pin style terminal contact blocks :
. Ø 1 mm
mm²
. Solid or stranded wire with ferrule : 2 x 0,5 mm² to 2 x 1,5 mm²
For Faston terminal contact blocks :
. 1 faston clip 6,35 mm or 2 faston clips 2,85 mm
For pin style terminal contact blocks :
. Ø 1 mm
Connection with screw and plug
Connection with screw and plug
Connection with screw and plug
Connection with screw and plug----in terminals
in terminals
in terminals
in terminals ::::
. Terminals protected against direct contact (IP2X)
. Recommended terminal torque: 1.2 Nm
. Recommended terminal torque: 1.2 Nm
4.
4.
4.
4. CONNECTION
CONNECTION
CONNECTION
CONNECTION
Tools
Tools
Tools
Tools ::::
. For plug-in terminals, it is advisable to use screwdriver with Flat
blade - 2.5 mm
. For screw terminals, it is advisable to use screwdriver Phillips
n°2 or screwdriver with flat blade - 5,5 mm
. To remove the block it is advisable to use a flat blade
screwdriver
blade - 2.5 mm
. For screw terminals, it is advisable to use screwdriver Phillips
n°2 or screwdriver with flat blade - 5,5 mm
. To remove the block it is advisable to use a flat blade
screwdriver
Connecti
Connecti
Connecti
Connecting
ng
ng
ng blocks on clips
blocks on clips
blocks on clips
blocks on clips ::::
Clip
single
3
positions
5
positions
1 level
X
X
X
Blocks
2 levels
X
6 and more NO blocks on a 3 position clip are unsuitable
with
EN418 push and turn mushroom head.
5.
5.
5.
5. TECHNICAL CHARACTERISTICS
TECHNICAL CHARACTERISTICS
TECHNICAL CHARACTERISTICS
TECHNICAL CHARACTERISTICS
Maximum operating current
Maximum operating current
Maximum operating current
Maximum operating current::::
. For standards blocks (screw or Plug-in terminals)
. AC15 (Alternating current)
- Ue = 120 V Ie = 8 A
- Ue = 230 V Ie = 6 A
- Ue = 400 V Ie = 4,5 A
- Ue = 440 V Ie = 3,5 A
- Ue = 500 V Ie = 2,5 A
- Ue = 690 V Ie = 1 A
. AC15 (Alternating current)
- Ue = 120 V Ie = 8 A
- Ue = 230 V Ie = 6 A
- Ue = 400 V Ie = 4,5 A
- Ue = 440 V Ie = 3,5 A
- Ue = 500 V Ie = 2,5 A
- Ue = 690 V Ie = 1 A
. DC13 (Direct current)
- Ue = 24 V Ie = 1,5 A
- Ue = 48 V Ie = 1 A
- Ue = 60 V Ie = 0,7 A
- Ue = 110 V Ie = 0,3 A
- Ue = 230 V Ie = 0,2 A
. For Pin style terminals blocks
. AC15 (Alternating current)
- Ue = 120 V Ie = 8 A
- Ue = 240 V Ie = 6 A
- Ue = 400 V Ie = 4 A
- Ue = 24 V Ie = 1,5 A
- Ue = 48 V Ie = 1 A
- Ue = 60 V Ie = 0,7 A
- Ue = 110 V Ie = 0,3 A
- Ue = 230 V Ie = 0,2 A
. For Pin style terminals blocks
. AC15 (Alternating current)
- Ue = 120 V Ie = 8 A
- Ue = 240 V Ie = 6 A
- Ue = 400 V Ie = 4 A
. DC13 (Direct current)
- Ue = 125 V Ie = 0,22 A
- Ue = 250 V Ie = 0,1 A
. For Faston terminal blocks
. AC15 (Alternating current)
- Ue = 120 V Ie = 6 A
- Ue = 240 V Ie = 3 A
. DC13 (Direct current)
- Ue = 125 V Ie = 0,55 A
- Ue = 250 V Ie = 0,27 A
- Ue = 125 V Ie = 0,22 A
- Ue = 250 V Ie = 0,1 A
. For Faston terminal blocks
. AC15 (Alternating current)
- Ue = 120 V Ie = 6 A
- Ue = 240 V Ie = 3 A
. DC13 (Direct current)
- Ue = 125 V Ie = 0,55 A
- Ue = 250 V Ie = 0,27 A
Creation date: 22/10/07