Behringer Xenyx 1204 USB Mixer XENYX 1204 USB Scheda Tecnica

Codici prodotto
XENYX 1204 USB
Pagina di 13
10
XENYX 1204/1204FX
3, 5 and 7 and in the second pass, on tracks 2, 4, 6 and 8.
CONTROL ROOM OUTPUTS
The control room output is normally connected to the monitor
system in the control room and provides the stereo mix or, when
required, the solo signal.
2.4.2 Voltage supply, phantom power and fuse
Fig. 2.15: Voltage supply and fuse
FUSE HOLDER
The console is connected to the mains via the cable supplied
which  meets  the  required  safety  standards.  Blown  fuses  must
only be replaced by fuses of the same type and rating.
IEC MAINS RECEPTACLE
The mains connection is via a cable with IEC mains connector.
An appropriate mains cable is supplied with the equipment.
POWER
Use the POWER switch to power up the mixing console.
PHANTOM
The  PHANTOM  switch  activates  the  phantom  power  supply
for the XLR connectors of the mono channels which is required
to operate condenser microphones. The red +48 V LED lights up
when  phantom  power  is  on.  As  a  rule,  dynamic  microphones
can  still  be  used  with  phantom  power  switched  on,  provided
that they are wired in a balanced configuration. In case of doubt,
contact the microphone manufacturer!
+
After  the  phantom  power  supply  has  been
switched  on,  do  not  connect  microphones  to  the
mixer  (or  the  stagebox/wallbox).  Connect  the
microphones  before  you  switch  phantom  power
on.  In  addition,  the  monitor/PA  loudspeakers
should  be  muted  before  activating  the  phantom
power  supply.  After  switching  on,  wait  approx.  one
minute  to  allow  the  system  to  stabilize.
+
Caution!  You  must  never  use  unbalanced  XLR
connectors  (PIN  1  and  3  connected)  on  the  MIC
input  connectors  if  you  want  to  use  the  phantom
power  supply.
SERIAL NUMBER
Please  note  the  important  information  on  the  serial  number
given in chapter 1.3.3.
3. DIGITAL EFFECTS PROCESSOR
Fig.  3.1:  Digital  effects  module  (only  1204FX)
24-BIT MULTI-EFFECTS PROCESSOR
Here you can find a list of all presets stored in the multi-effects
processor.  This  built-in  effects  module  produces  high-grade
standard  effects  such  as  reverb,  chorus,  flanger,  delay  and
various combination effects. The integrated effects module has
the  advantage  of  requiring  no  wiring.  This  way,  the  danger  of
creating ground loops or uneven signal levels is eliminated at the
outset, completely simplifying the handling.
These effect presets are designed to be added to dry signals.
If you move the FX TO MAIN control, you mix the channel signal
(dry)  and  the  effect  signal.
This also goes for mixing effects signals with the monitor mix.
The  main  difference  is  that  the  mix  ratio  is  adjusted  using  the
FX TO MON control. Of course, a signal has to be fed into the
effects processor via the FX control in the channel strip for both
applications.
+
On  the  following  page,  you  will  find  an  illustration
showing  how  to  connect  your  foot  switch  correctly.
LEVEL
The LED level meter on the effects module should display a
sufficiently high level. Take care to ensure that the clip LED only
lights up at peak levels. If it is lit constantly, you are overloading
the effects processor and this could cause unpleasant distortion.
The FX control (AUX SEND 2) determines the level that reaches
the  effects  module.
PROGRAM
You  can  select  the  effect  preset  by  turning  the  PROGRAM
control. The display flashes the number of the current preset. To
recall the selected preset, press the button; the flashing stops.
You can also recall the selected preset with the foot switch.
3. DIGITAL EFFECTS PROCESSOR