Typ
Colour
Part nr.
LC-Mini 120
white
91051
LC-Mini 120
black
91071
LC-Mini 180
white
91052
LC-Mini 180
black
91072
Accessory:
RC-Suppressor 10880
15. Article / Part nr. / Accessory
14. 
Technical data 
 
Power supply:        
230 V~ ±10 %
Detection area: LC-Mini  120
 
120°
 
LC-Mini 180
 180°
Range of coverage in m:  
max. 10 m when walking across (tangential
)
Degree of protection/class:  
IP 44 / II / 
Dimension: 
L 80 x B 55 x H 70 mm
Ambiente temperature:  -25°C to +50°C
Package: 
Housing UV- and shock-resistant Polycarbonate
Chanel 1 for light control
Contact load: 
1000 W, cosφ = 1
Time-settings: 
4 s - 10 min.
Brightness value: 
2 - 2000 Lux
 
Declaration of Conformity: 
The product complies with the low voltage 
recommendation 2006/95/EC/ and the EMV 
recommendation 2004/108/EC.
12. Dimensions (mm)
M
A
N 6
93
– 1
8111
3-
3
11. Wiring diagrams
N
L
N
L
L‘
C 1
E 1
L
N
E 1
S 1
RC
N
L
L‘
C 1
N
N
L
L
L‘
C 1
E 1
T 7
L
L
L
C 1
C 1
L‘
L‘
N
N
N
E 1
L
L
L
L‘
N
N
N
E 1
T 1
T 2
30 s - 
10 min.
4
3
13. Trouble Shooting-Practical hints
 
1. Lamp does not light up
Cause - Action
Lamp is defective
- Replace light bulb.
No mains connection
- Check mains fuse.
Switching threshold of the twilight switch is not 
correct 
-  Accordingly adjust sensitivity of twilight 
switch via the setting dial.
Detection area not set correctly
Set detection area correctly.
Unit mounted too high
-  Mount at recommended height (2.50 m) 
PIR detector lens obstructed by dirt or other 
objects
- Clean lens or remove objects
2. Delayed lamp activation
Mounted too high
- Mount at height stated in specification 
(2.5 m)
Only direct in-line approach of detector is 
possible 
-  Mount detector in such a way that a  
sideways approach is also detected.
3. Lamp stays on continuously
Continuous thermal movement within detection 
area 
-  Remove the heat source out of the detection 
area.
Check the correct functioning of the detector 
in fully covering the lens (lights should go out 
after a certain time-delay).
Motion detector is switched parallel to a switch 
that enables direct manual switching on 
- Mind the correct connection of the switch.
4.  Light source remains on for long periods 
when no persons are present
Permanent influence from heat sources within 
detection area (trees, shrubs when blown by 
the wind, presence of animals like cats and 
dogs in the detection area)
-  Reduce detection area of the detector in 
turning the detector head downward or 
cover parts using the enclosed covers.
Direct sunlight radiation into detector lens
- Shelter lens from direct sunlight.
Detector mounted above extractor fan
- Change mounting place of the detector.
5.  Limitation of range (not up to the minimum 
specification)
Mounting height is not optimal
-  Accordingly change mounting height 
(2.50 m).Persons only move directly towards 
the detector
-  Mount detector in such a way that a  
sideways approach is also detected.
Steep terrains
- Adjust spherical head accordingly.
6. No reaction to vehicles
Vehicle not warmed up
Vehicle is well insulated (by silencing equip-
ment)
Standard mode with 1-channel motion detector
Standard mode with 1-channel motion detector with  
permanent light function
Standard mode with 1-channel motion 
detector with NC pushbutton
Parallel connection with 1-channel motion detectors
Standard mode with 1-channel motion detector 
(e.g. stairs)
optional:
S1 =
 switch for permanent light
RC = 
RC-suppression kit if required
T 1 = NC button
 
Manual switching addition-
ally possible (press opener 
approx. 2 sec.).
38
7
41
10
7
48
22
58
22
L
N
L’