Keba 89.423 Electric Cars KEBA 89.423 Electric Cars N/A Silver, Grey Silver, Grey 89.423 Scheda Tecnica

Codici prodotto
89.423
Pagina di 48
Installation guidelines
 KeContact 
P20 
14 
Installation
 manual, Version: 1.41 / Article no.: 90064 
 
© KEBA 2012-2013 
Differing requirements for the fullfillment of „Z.E.-Ready®“ (Renault) 
 
  13A charging cables must not be used 
  For 3-phase connection of the KeContact P20, a RCD circuit breaker Type B must be 
used. 
  Renault recommends the selection of the line circuit breaker according to the follow-
ing table: 
 
Characteristics 
Preadjusted charging current 
value (DIP-switch setting) 
Line circuit breaker 
1-phase 
3-phases 
10A 
not allowed!
 
13A 
not allowed!
 
16A 
20A 
D
 
20A 
25A 
D
 
25A 
32A 
D
 
32A 
32A 
C
 
 
The nominal current of the selected line circuit breaker must not exceed the value on 
the type plate. If the preadjusted charging current setting and the nominal current are 
equal, in particular the temperature in the switching cabinet must be considered 
(thermal derating of the line circuit breaker). 
 
3.3  Space requirements 
 
Space requirements – dimensions in millimeters 
Space requirements 
For device versions with optional cable hanger, 
additional and sufficient free area (y) for the 
charging cable to be used is to be accounted 
for. 
 
If several charging stations are installed adja-
cent to each other, a distance of at least 200 
mm between charging stations must be com-
plied with.