Differing requirements for the fullfillment of „Z.E.-Ready®“ (Renault)
13A charging cables must not be used
For 3-phase connection of the KeContact P20, a RCD circuit breaker Type B must be
used.
Renault recommends the selection of the line circuit breaker according to the follow-
ing table:
Characteristics
Preadjusted charging current
value (DIP-switch setting)
Line circuit breaker
1-phase
3-phases
10A
not allowed!
13A
not allowed!
16A
20A
C
D
20A
25A
C
D
25A
32A
C
D
32A
32A
B
C
The nominal current of the selected line circuit breaker must not exceed the value on
the type plate. If the preadjusted charging current setting and the nominal current are
equal, in particular the temperature in the switching cabinet must be considered
(thermal derating of the line circuit breaker).
3.3 Space requirements
Space requirements – dimensions in millimeters
Space requirements
For device versions with optional cable hanger,
additional and sufficient free area (y) for the
charging cable to be used is to be accounted
for.
If several charging stations are installed adja-
cent to each other, a distance of at least 200
mm between charging stations must be com-
plied with.
For device versions with optional cable hanger,
additional and sufficient free area (y) for the
charging cable to be used is to be accounted
for.
If several charging stations are installed adja-
cent to each other, a distance of at least 200
mm between charging stations must be com-
plied with.