07-01583B  06-07 Copyright 2007 Dri-Eaz Products, Inc.                              1
 
 
 
 
Owner’s Manual –  
Dri-Eaz
®
 EnviroBoss
 1400  
DRI-EAZ PRODUCTS, INC.  
15180 Josh Wilson Road, Burlington, WA USA 98233 
Fax: (360) 757-7950
  Phone US: (360) 757-7776   www.dri-eaz.com  
The EB1400 is a highly transportable system, offering cooling, heating and dehumidification. It’s ductable for spot cooling 
and directing conditioned air or heat into specific spaces. 
Read And Save These Instructions 
 
 
 
 
 
 
 
 
 
 
Read and understand manual before operating.
 
 
ELECTRIC SHOCK HAZARD 
WARNING! Unit must be grounded. 
• 
Use indoors only. 
• 
Keep out of water. 
• 
Keep electrical components dry. If they get wet, allow 
them to dry before using the EB1400. 
• 
Insert 3-prong plug on power cord into a matching 
electrically grounded outlet. Never cut off third prong. 
 
FIRE HAZARD 
• 
Keep air intakes clear of obstructions and dirt. 
Reduced airflow can cause motor to overheat. Keep 
away from draperies or other material that could block 
air intakes. See maintenance instructions. 
• 
Keep air filter clean. Keep filter clear of clogging, oil, 
grease or other contaminants that can be drawn into 
the EB1400.  
 
SAFETY INSTRUCTIONS 
WARNING! Unplug unit before opening housing for 
cleaning or servicing
• 
Turn off unit and unplug before lifting or moving. 
• 
Handle the unit carefully. Always operate the unit on a 
stable, level surface. Do not drop, throw, or place 
where it could fall. Rough treatment can damage the 
unit, and may create a hazardous condition or void 
the warranty. 
• 
Inspect the power cord before use. If cord is 
damaged, do not use. Replace with a cord of the 
same type and amperage rating. Protect cord from 
damage by turning off unit before unplugging. Always 
grasp the plug (not pulling on the cord) to unplug. 
• 
The unit is designed to operate on a 115V/60 Hz,  
15-amp circuit. Make sure that the electrical outlet is 
grounded.   
• 
Secure during transport to prevent sliding and 
possible injury to vehicle occupants. 
• 
Keep children away from unit. Be sure unit is 
inaccessible to children when unattended. 
• 
Do not attempt to disassemble or repair the unit.  
For Authorized Service Centers, go to  
www.dri-eaz.com/HOWTOBUY
 or call Dri-Eaz 
Service at 800-932-3030. 
 
INTRODUCTION 
The EB1400 is a versatile unit providing dehumidification, 1-ton 
cooling with 470 CFM across the evaporator and 750 CFM 
across the condenser, plus focused heating and ventilation. 
The unit is ductable for spot cooling and directing conditioned 
air or heat into specific spaces while filtering room air and 
pumping out condensate. 
FEATURES:  
• 
Ducts to and from unit for heating and cooling.  
Note: Duct adapters for condenser inlet and outlet 
and evaporator outlet.  No duct adapter for evaporator 
inlet 
• 
Refrigeration system that dehumidifies while it heats 
or cools 
• 
Uniform 8” ducting size for all outlets 
 
• 
Digital temperature control  
• 
Durable rotomolded duct rings and housing 
• 
Wheel casters for ease of transport 
 
WARNING