GSI Outdoors PNEG-630 Manuale Utente

Pagina di 121
Portable Dryer Troubleshooting
37
Meter Roll Reversing
14
9
13
12
1
4
8
5
   TO
DC DRIVE
 MOTOR
ORANGE
      
PURPLE
      
J7-17
      
NOTE:
      WHEN INSTALLING RELAY
      BASE NOTE POSITION OF
      SLOTS FOR RELAY!!
JUMPER WIRES SHOULD
    GO BETWEEN:
 TERMINALS 4 AND 5
 TERMINALS 1 AND 8
      
A+
J8-20
      
A-
ORANGE
      
PURPLE
      
WHITE
      
BLACK
      
YOU MUST ADD A JUMPER WIRE
FROM J9-09 TO J7-16 IN THE
LOWER CONTROL BOX.
(110 VAC CONTROL)
(110 VAC NEUTRAL)
REVERSE DELAY = METER ROLLS NORMAL ROTATION TIME
(AMOUNT OF TIME METER ROLLS WILL OPERATE BEFORE 
THEY WILL BEGIN REVERSE ROTATION)
REVERSE TIME = METER ROLLS REVERSE ROTATION TIME
(AMOUNT OF TIME METER ROLLS WILL OPERATE IN THE 
REVERSED ROTATION MODE)
EXAMPLE: REVERSE DELAY = 10 MINUTES
         REVERSE TIME  =  1 MINUTE
YOU MUST ENTER INTO THE DRYER
PARMETER MODE BY PRESSING THE
INCREASE AND DECREASE BUTTONS
SIMULTANIOUSLY. YOU WILL HAVE
THE FOLLOWING OPTIONS LISTED:
  SHUTDOWN HISTORY (PRESS ENTER)
  DRYER MODEL # (IE. 1112)
  FAN DELAY       (DEFAULT = 5)
  FILL AUGER      (DEFAULT = END)
  BPH FACTOR      (DEFAULT = 1.0)   
  TEST METER ROLL (DEFAULT = YES)
  TEST AIR SWITCH (DEFAULT = YES)
  M.R. REVERSE    (DEFAULT = NO) <- CHANGE TO YES
  * REVERSE DELAY (DEFAULT = 60)
  * REVERSE TIME  (DEFAULT = 1)
* DISPLAYED ONLY IF M.R. REVERSE
  IS CHANGED TO YES
 
   TO
SCR DRIVE
  BOARD
 LOCATE THE ORANGE AND
PURPLE WIRES COMING FROM
THE SCR DRIVE BOARD GOING
TO THE TERMINAL STRIP AND
INSERT THE RELAY AS SHOWN
A-
A+
IMPORTANT
 Wiring Reference