GSI Outdoors PNEG-630 Manuale Utente

Pagina di 121
Portable Dryer Troubleshooting
77
 Competitor Wiring Reference
Series 100 Control Box Wiring
100STRIP98.PRT     REV. DATE 3/12/98
1 - END PROTECTOR# D01-0532
48 - COMPRESSION TERM.# D01-0531
2 - ENDSTOP# D01-0533
4 - GROUND TERMINAL# D01-0534
13" DIN RAIL# D03-0013
+12 VOLTS
HOUSING HIGH LIMIT
VAPOR HIGH LIMIT
REAR DISCHARGE
OUT OF GRAIN
AIRFLOW
AIR GND
FLAME DETECT
FLAME DETECT
PLENUM TEMPERATURE
GRAIN/PLENUM GND
GRAIN TEMPERATURE
MAIN SOLENOID NEUTRAL
MAIN SOLENOID POWER
CYCLE SOLENOID POWER
UNLOAD AUGER NEUTRAL
UNLOAD AUGER POWER
LOAD AUGER NEUTRAL
LOAD AUGER POWER
FAN POWER
FAN NEUTRAL
IGNITION NEUTRAL------
IGNITION POWER
+12 VOLTS
+12 VOLTS
RED
RED
BLK
YEL
  - - PURP
ORG
ORG
WHT
BLK
BLUE
YEL
WHT/BLK
BLK
-WHT
BLK
WHT
WHT
WHT
BLK
BLK
BRN
BLK
BLK
WHT
2 WIRES WHT/BLK
+12 VOLTS
BRN
LEFT GRAIN HI- 2 WIRES ORG
PLENUM HIGH LIMIT
- -BLUE
RED - - - -J7-02
NO AIRFLOW
GRY
NO CONNECTION
WORK LIGHT NEUTRAL
WORK LIGHT POWER
WHT
RED
METERING ROLL POT
BLK
METERING ROLL POT
BLK
METERING ROLL POT
BLK
RIGHT GRAIN HI 2 WIRES RED
NO CONNECTION
RED - - - -J7-08
RED - - - -J1-13
RED - - - -J7-03
RED - - - -J7-05
                 (MOTOR OVERLOAD-49)
RED - - - -J7-04 (MOTOR OVERLOAD-35)
BLUE- - - -J7-09
WHT - - - -J7-10
BLUE- - - -J7-11
GREY- - - -J7-19
WHT - - - -J7-20
YEL - - - -J7-12
WHT - - - -J7-13
RED - - - -J7-01
ORG - - - -J7-14
WHT - - - -J6-02
BLK - - - -AC-01
WHT - - - -J6-13
BLK - - - -M-SOL
BLK - - - -J6-14
WHT - - - -J3-02
ORG - - - -J3-01
WHT - - - -J3-12
YEL - - - -J3-11
WHT - - - -J3-14
BLUE- - - -J6-03
WHT - - - -J6-07
BLK - - - -J6-06
WHT - - - -J3-18
ORG - - - -J6-09
PUR - - - -J4-02
PUR - - - - SCR2
PUR - - - -J4-01
WHT - - - -J6-18
BLK - - - - LITE
ORG - UNLOAD AUX COM
ORG - UNLOAD AUX N/O
YEL - LOAD AUX COM
YEL - LOAD AUX N/O
NO CONNECTION (12 VDC CENTER TAP)
NO CONNECTION (12 VDC CENTER TAP)
NO CONNECTION (12 VDC CENTER TAP)
NO CONNECTION (12 VDC CNTR TAP)
NO CONNECTION
NO CONNECTION
NO CONNECTION
SCR CONTACTOR NEUTRAL
SCR CONTACTOR POWER -
WHT
ORG
USER INSTALLED
USER INSTALLED
USER INSTALLED
USER INSTALLED
2 WIRES -
2 WIRES -
MERCOID SWITCH (CANADA ONLY)
PINK------------ J1-16
MAXON NEUTRAL -------- WHT
WHT - - - -J3-04
MAXON POWER ---------- PUR
BLK - - - -J3-03
16 GA WIRES
RED - - - -J1-17 USER SAFETY
NO CONNECTION (12VDC CNTR TAP)
REMOVE SCREW TO ACTIVATE 
USER SAFETY TERMINAL
CONNECT WIRE FROM J7-08
THRU USER SAFETY SWITCH
BACK TO USER SAFETY TERM.