Machine Specifications
Copier/Printer
Continued
*Features, configurations and options may vary by location.
1
With Office Finisher.
ELECTRICAL REQUIREMENTS
ACCESSORY OPTIONS* (Continued)
POWER CONSUMPTION
1
5632/5638 Copier
1
5632/5638 Copier/Printer
1
5645/5655 Copier
1
5645/5655 Copier/Printer
1
Running
≤ 1080 watts
≤ 1130 watts
≤ 1180/1280 watts
≤ 1280/1380 watts
Standby
≤ 265 watts
≤ 305 watts
≤ 265 watts
≤ 305 watts
Low Power Mode
≤ 100 watts
≤ 125 watts
≤ 100 watts
≤ 135 watts
Auto Off / Sleep mode
≤ 4 watts
≤ 9 watts
≤ 4 watts
≤ 9 watts
Warm up to Copy
≤ 28 seconds
≤ 28 seconds
≤ 28 seconds
≤ 28 seconds
Ready to Print
NA
≤ 130 seconds
NA
≤ 130 seconds
Low Power Recovery
≤ 9 seconds
≤ 9 seconds
≤ 9 seconds
≤ 9 seconds
ENVIRONMENTAL CONSIDERATIONS
Required Temperature Range
Required Temperature Range
10° to 32° C
Required Relative Humidity
10% to 85%
Walkup Fax with LAN Fax: One line and Two lines
USB 2.0 / (IEEE1284) Parallel Port Kit (Available with Copier/Printer/Scanner only)
Scan to PC Desktop SE and Professional (Available with Copier/Printer/Scanner only)
Xerox Unicode International Printing Kit
Enablement for Network Accounting and Xerox Business Alliance Partner Solutions
Upgrade Kit to Copier/Printer/Scanner (includes Network Scanning, Scan to Email, Network Server Fax and Internet Fax)
USB 2.0 / (IEEE1284) Parallel Port Kit (Available with Copier/Printer/Scanner only)
Scan to PC Desktop SE and Professional (Available with Copier/Printer/Scanner only)
Xerox Unicode International Printing Kit
Enablement for Network Accounting and Xerox Business Alliance Partner Solutions
Upgrade Kit to Copier/Printer/Scanner (includes Network Scanning, Scan to Email, Network Server Fax and Internet Fax)
110-140 Volt Nominal, 60 Hz, 15A (North America)
220-240 Volt Nominal, 50 Hz, 10A (Europe)
Note: Convenience Stapler requires separate 110V 15A circuit
220-240 Volt Nominal, 50 Hz, 10A (Europe)
Note: Convenience Stapler requires separate 110V 15A circuit