HP Storageworks HSG80 Manuale Utente

Pagina di 18
Common Platform Issues
9
Using Switch Zoning to Prevent Crashes When the 96-Connection Limit Is Exceeded
The HSG80 controller may crash if more than 96 connections exist on the fabric. HP suggests 
that you use switch zoning to limit the number of connections visible to a single HSG80 
controller. For more information about switch zoning, refer to the HP StorageWorks Data 
Replication Manager HSG80 ACS Version 8.7P Configuration Guide
.
I/O Pause During Fabric Reconfiguration
During a fabric reconfiguration, you will notice a brief pause in I/O functions on all servers 
connected to the fabric. This brief cessation of read/write operations is normal. A fabric 
reconfiguration can be caused by switches starting up or shutting down, and by the physical 
plugging or unplugging of fiber cables.
Controller Saturation
High usage of many remote copy set and nonremote copy set LUNs has a serious impact on 
the performance of the remote copy set LUNs, causing controller saturation and possibly 
starving a full copy operation. 
A saturated controller condition begins approximately when idle time falls to 25% or less 
when viewed through VTDPY. When this occurs, you may see Aborted Command errors 
through the Command Line Interface (CLI). 
To prevent controller saturation:
Avoid placing multiple heavy-use loads on the controllers.
Use the VTDPY screen to monitor controller idle time percentage. Adjust load to maintain 
an idle time of 25% or greater.
RAID 5 Remote Copy Set Target Drop
Under the following combined conditions, RAID 5 remote copy set targets may be dropped:
No write history log disk is configured, and
Host I/O is accessing the initiator remote copy set LUNs.
When both target controllers are shut down, a full copy operation is triggered. When the target 
controllers are restarted, they will begin a 3-minute memory diagnostic.
While the memory diagnostics are running, the full copy I/O to RAID 5 target LUNs is stalled. 
Therefore, after approximately 2 minutes, a timeout occurs and the target LUNs are dropped 
from the remote copy set. This target drop problem occurs only on RAID 5 remote copy set 
LUNs.
To prevent target LUN drop:
1.
Set port_2_topology on both initiator controllers to offline before target controllers are 
booted and powered on.
2.
Wait five minutes after target controllers are restarted to allow for memory diagnostics 
to complete.
3.