BENDIX TCH-008-038 Dépliant

Pagina di 2
Technical 
Bulletin
Bulletin No:
Effective Date:
Cancels:
Page:  1 of
Subject:
© 2006 Bendix Commercial Vehicle Systems LLC All rights reserved.  3/2006 Printed in U.S.A.
TCH-008-038
03-28-2006
Same dated 04-08-2005
2
Cyclone DuraDrain
™ 
Trailer Water Separator
In addition to the service information presented in the Cyclone DuraDrain
 trailer water separator Service Data
Sheet SD-08-2402 dated 8/2004, it is recommended that the following service intervals be followed to ensure
proper maintenance.  Also included are additional guidelines for troubleshooting air leakage in the Cyclone
DuraDrain
 trailer water separator.
CYCLONE DURADRAIN
SERVICE INTERVALS
Service intervals are dependent on specific environmental and operational factors that control the amount of
contamination removed by the Cyclone DuraDrain
 unit.  Experience should be used to determine how frequently
the unit must be serviced.  As a recommended minimum, every 12 months, 100,000 miles or 3,600 operating
hours, perform the Operational and Leakage Tests.  As indicated in the Service Data Sheet, inspect the
Cyclone DuraDrain
 unit for unrestricted airflow and blockage from debris collection.  Remove the purge nut
and service according to the “Disassembly and Cleaning” instructions.
CYCLONE DURADRAIN
 TRAILER WATER SEPARATOR AIR LEAKAGE TROUBLESHOOTING
This is the recommended troubleshooting procedure should an audible air leak be detected from the Cyclone
DuraDrain
 trailer water separator.  Be sure to review and follow all safety guidelines in the Service Data Sheet
before servicing the DuraDrain
 trailer water separator.
DO NOT DISCONNECT OR REMOVE THE CYCLONE DURADRAIN
 BODY.
All servicing can be done without disconnecting the air lines and without removing the Cyclone DuraDrain
trailer water separator body.  All servicing is done to the removable hex purge nut located on the bottom.  See
the illustration below.
O-ring
Hex Purge Nut
Cyclone DuraDrain
trailer water separator