engine be in operation, EXTREME CAUTION should
be used to prevent personal injury resulting from
contact with moving, rotating, leaking, heated or
electrically charged components.
be used to prevent personal injury resulting from
contact with moving, rotating, leaking, heated or
electrically charged components.
3.
Do not attempt to install, remove, disassemble
or assemble a component until you have read
and thoroughly understand the recommended
procedures. Use only the proper tools and
observe all precautions pertaining to use of those
tools.
or assemble a component until you have read
and thoroughly understand the recommended
procedures. Use only the proper tools and
observe all precautions pertaining to use of those
tools.
4.
If the work is being performed on the vehicle’s
air brake system, or any auxiliary pressurized air
systems, make certain to drain the air pressure
from all reservoirs before beginning ANY work
on the vehicle. If the vehicle is equipped with an
AD-IS
air brake system, or any auxiliary pressurized air
systems, make certain to drain the air pressure
from all reservoirs before beginning ANY work
on the vehicle. If the vehicle is equipped with an
AD-IS
®
air dryer system or a dryer reservoir
module, be sure to drain the purge reservoir.
5.
F o l l o w i n g t h e v e h i c l e m a n u f a c t u r e r ’ s
recommended proc edures, deac tivate the
electrical system in a manner that safely removes
all electrical power from the vehicle.
recommended proc edures, deac tivate the
electrical system in a manner that safely removes
all electrical power from the vehicle.
6.
Never exceed manufacturer’s recommended
pressures.
pressures.
7.
Never connect or disconnect a hose or line
containing pressure; it may whip. Never remove
a component or plug unless you are certain all
system pressure has been depleted.
containing pressure; it may whip. Never remove
a component or plug unless you are certain all
system pressure has been depleted.
8.
Use only genuine Bendix
®
replacement parts,
components and kits. Replacement hardware,
tubing, hose, fi ttings, etc. must be of equivalent
size, type and strength as original equipment and
be designed specifi cally for such applications and
systems.
tubing, hose, fi ttings, etc. must be of equivalent
size, type and strength as original equipment and
be designed specifi cally for such applications and
systems.
9.
Components with stripped threads or damaged
parts should be replaced rather than repaired.
Do not attempt repairs requiring machining or
welding unless specifi cally stated and approved
by the vehicle and component manufacturer.
parts should be replaced rather than repaired.
Do not attempt repairs requiring machining or
welding unless specifi cally stated and approved
by the vehicle and component manufacturer.
10. Prior to returning the vehicle to service, make
certain all components and systems are restored
to their proper operating condition.
to their proper operating condition.
11.
For vehicles with Automatic Traction Control
(ATC), the ATC function must be disabled (ATC
indicator lamp should be ON) prior to performing
any vehicle maintenance where one or more
wheels on a drive axle are lifted off the ground
and moving.
(ATC), the ATC function must be disabled (ATC
indicator lamp should be ON) prior to performing
any vehicle maintenance where one or more
wheels on a drive axle are lifted off the ground
and moving.
REMOVAL
Disconnect both upstream glad-hands from the trailer or
dolly before beginning work on the Cyclone DuraDrain
dolly before beginning work on the Cyclone DuraDrain
™
trailer water separator.
1. Disconnect the supply and delivery line fi ttings.
2. Remove the mounting hardware, and spacer if
applicable, that secures the Cyclone DuraDrain
™
trailer
water separator to the trailer frame rail.
INSTALLATION
A Cyclone DuraDrain
™
trailer water separator can be
installed in the control and/or the supply line of the trailer
between the glad-hand and the fi rst valve in the trailer
system. See Figure 3 Trailer Schematic.
between the glad-hand and the fi rst valve in the trailer
system. See Figure 3 Trailer Schematic.
1. Identify the control and/or the supply line that the
Cyclone DuraDrain
™
trailer water separator is to be
installed in. The trailer water separator should be
installed at the lowest point on the air line, but should
not be too low causing a dip in the air line. The Cyclone
DuraDrain
installed at the lowest point on the air line, but should
not be too low causing a dip in the air line. The Cyclone
DuraDrain
™
trailer water separator must be installed
vertically with the purge nut pointing down to the ground
to allow for adequate draining.
to allow for adequate draining.
2. Locate a mounting position on the trailer frame rail or
cross-member. Using the Cyclone DuraDrain
™
trailer
water separator as a template, mark the location of the
mounting holes. Drill two mounting holes. Consult with
the trailer manufacturer prior to drilling any holes in the
frame rail or cross-member. If a mounting spacer is
used, install as shown in Figure 2. Secure using grade
2 or 5 mounting hardware.
mounting holes. Drill two mounting holes. Consult with
the trailer manufacturer prior to drilling any holes in the
frame rail or cross-member. If a mounting spacer is
used, install as shown in Figure 2. Secure using grade
2 or 5 mounting hardware.
3. Cut the air line and install a 3/8” NPT male fi tting at each
end. Connect the air lines to the supply and delivery
ports of the Cyclone DuraDrain
ports of the Cyclone DuraDrain
™
trailer water separator.
FIGURE 2 - INSTALLATION
CYCLONE DURADRAIN
™
TRAILER WATER
SEPARATOR
MOUNTING SPACER
(KIT 5014792)
MOUNTING BOLTS
WASHER
NUT