Furuno RC-1500-1T Manuale Utente

Pagina di 418
7-8
7.8
Scan Freq Menu
The Scan freq menu determines which DSC routine and distress frequencies to scan. Follow the
instructions below to select/deselect DSC routine and distress frequencies to scan.
7.8.1
Distress frequencies
1.  Press the [#/SETUP] key, select SCAN FREQ and press the [ENT] key to display the SCAN
FREQ menu.
DISTRESS
  2M  :  
FIXED
  4M  :  
ON
  6M  :  ON
  8M  :  
FIXED
12M  :  ON
16M  :  OFF
**
 Scan freq setup 
*
ROUTINE
F1  :
   
2M-INTL
F2  :   4M-INTL
F3  :   6M-INTL
F4  :   8M-INTL
F5  : 16M-INTL
F6  : 25M-INTL
2. Press 

 to shift the cursor to the DISTRESS column.
3.  Select the frequency to process and press the [ENT] key. For example, select 4 MHz.
ROUTINE
F1  :   2M-INTL
F2  :   2M-USR3
F3  :   4M-INTL
F4  :   8M-INTL
F5  : 16M-LCL1
F6  : 25M-LCL2
DISTRESS
  2M  :  
FIXED
  
4M  :  ON
  6M  :  ON
  8M  :  
FIXED
12M  :  ON
16M  :  OFF
**
 Scan freq setup 
*
ON
OFF
4.  Select ON or OFF as appropriate and press the [ENT] key.
5.  Press the [CANCEL] key twice to return to the DSC standby screen.
Note: Regulations require that 2 MHz and 8 MHz be watched continuously. These frequencies
cannot be turned off. Maximum three bands may be turned off.