Furuno RC-1500-1T Manuale Utente

Pagina di 418
8-1
 
8. CHECKING, MAINTENANCE
WARNING
Do not open the equipment.
Hazardous voltage which can
cause electrical shock exists
inside the equipment. Only 
qualified personnel should 
work inside the equipment.
8.1
Daily Test
Authorities require that the equipment be checked daily for proper operation to ensure that it will
function properly in the event of distress. Execute the daily test as below.
1.  At the DSC standby screen or radiotelephone setting screen, press the [3/TEST] key to start
the test.
2.  After several seconds the test results appear followed by the audio alarm. OK denotes
normal operation, and NG (No Good), error. For NG (No Good) contact your dealer for
advice.
  
  
: OK  VER.XX* 
MAIN CPU 
MODEM 
RCVR1 
RCVR2 
REMOTE RT 
REMOTE DP
: OK  VER.XX* 
: OK 
: OK 
: OK  FS1562 
: OK  DP-6
**
DSC-60 daily test
 
**
MAIN CPU:
ROM/RAM test executed and version no. displayed.
MODEM:
DSP ROM and DSC signal loopback tests executed and
version no. displayed.
RCVR1:
Distress/safety watch received tested.
RCVR2:
Routine watch receiver (option) tested.
REMOTE RT:
CAID of MIF command sent and received. Name of 
equipment connected (if FURUNO make) and result appear.
(System setting RP PORT must be set for RT or MIF otherwise 
nothing appears.)
REMOTE DP:
CAID of MIF command sent and received. Name of 
equipment connected (if FURUNO make) and result appear.
(Nothing appears when system setting NBDP PORT is OFF.)
Alarm:
Distress alarm sounds for two seconds after completion
of test.
* XX =  Version number
JAN-01-2000-15:24