Texas TMS320C645X Manuale Utente

Pagina di 218
www.ti.com
5.94
Port Error Detect CSR n (SPn_ERR_DET)
SRIO Registers
Each of the four ports is supported by a register of this type.
Figure 150. Port Error Detect CSR (SPn_ERR_DET)
31
30-24
23
22
21
20
19
18
17
16
ERR_I
Reserved
Invalid
CORR CNTL_
RCVD
PKT_
RCVD
RCVD
Reserv
MP_S
UPT_
SYM_
_PKT_
UNEX
_PKT_ _PKT_
ed
PECIF
CNTL_
UNEX
NOT_
PECT
WITH_
OVER
IC
SYM
PECT
ACCP
ED_A
BAD_
_276B
ED_A
T
CKID
CRC
CKID
RC-
R-0x00
R-
RC-
RC-
RC-
RC-
RC-
RC-
R-
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
LEGEND: R = Read only; -= value after reset
15-6
5
4
3
2
1
0
Reserved
NON_
PROT
Reserv DELIN
UNSO
LINK_
OUTS
OCOL
ed
EATIO LICITE TIMEO
TANDI
_ERR
N_ER
D_AC
UT
NG_A
OR
ROR
K_CN
CKID
TL_SY
M
R-0x00
RC-
RC-
R-
R-
RC-
RC-
0x00
0x00
0x00
0x00
0x00
0x00
LEGEND: R = Read only; -= value after reset
Table 124. Port Error Detect CSR (SPn_ERR_DET) Field Descriptions
Bit
Field
Value
Description
31
ERR_IMP_SPECI
An implementation specific error has been detected. It covers illegal field of Maintenance packet
FIC
error, illegal destination ID, not supported transaction.
30-24
Reserved
Reserved
23
Invalid
Reserved. Received a packet/control symbol with an S-bit parity error (Not Valid for SERIAL)
22
CORRUPT_CNTL
Received a control symbol with a bad CRC value (serial)
_SYM
21
CNTL_SYM_UNE
Received an acknowledge control symbol with an unexpected ackID (packet-accepted or
XPECTED_ACKI
packet-retry). The Capture Registers don't have valid information during this error detection.
D
20
RCVD_PKT_NOT
Received packet-not-accepted acknowledge control symbol
_ACCPT
19
PKT_UNEXPECT
Received packet with unexpected ackID value- out-of-sequence ackID
ED_ACKID
18
RCVD_PKT_WIT
Received packet with a bad CRC value
H_BAD_CRC
17
RCVD_PKT_OVE
Received packet which exceeds the maximum allowed size
R_276B
16-6
Reserved
Reserved
5
NON_OUTSTAN
Link-response received with an ackID that is not outstanding. The Capture Registers don't have
DING_ACKID
valid information during this error detection.
4
PROTOCOL_ER
An unexpected packet or control symbol was received
ROR
3
Reserved
Reserved
2
DELINEATION_E
Received unaligned /SC/ or /PD/ or undefined code-group (serial). The Capture Registers don't
RROR
have valid information during this error detection.
1
UNSOLICITED_A
An unexpected acknowledge control symbol was received
CK_CNTL_SYM
0
LINK_TIMEOUT
An acknowledge or link-response control symbol is not received within the specified time-out
interval. The Capture Registers don't have valid information during this error detection.
Serial RapidIO (SRIO)