BENDIX BW2763 Dépliant

Pagina di 1
1.  Chock the vehicle wheels.  Start the engine and charge the air brake system to 
governor cut-out, around 130 psi.
2.  The primary and secondary air gauges will start to rise.   As the system pressure 
reaches the cut-out pressure, the gauges will stop moving and the air dryer will 
purge.  When the air dryer purges, the secondary gauge will drop 8 to 14 psi.
3.  Shut off the engine and push in the yellow button to release the parking brakes.  
Note that the gauges will drop a small amount.  Check the air gauges and 
if either gauge indicates a continued loss of pressure, check the system for 
leaks.
4.  Apply and hold the service brakes by fully depressing the brake pedal.  The 
gauges will drop a small amount.   Again, check for a loss of pressure by watching 
both gauges.   If either gauge indicates a continued loss of air pressure, check 
the system for leaks.
5.  Release the service brakes.  Continue to apply and release the service brakes 
until the pressure drops below governor cut-in (approximately 100 psi).  Both 
gauges will show a drop in pressure with each brake application.  If the system 
air pressure goes below 60 psi, the low pressure indicators will activate.
F i e l d   I n s p e c t i o n
6.  Start the engine and charge the air brake system again.  Turn the engine off.
7.  Locate and drain the primary reservoir.  Both dash air gauges will indicate 
a pressure drop.   The secondary reservoir, which is not being drained, will 
stop showing a drop in pressure above 90 psi.  If both continue to drain, this 
indicates that the secondary reservoir has a defective, or missing, pressure 
protection valve such as the SC-PR
™ 
single check protection valve.
 
8.  Install or service the SC-PR
™ 
single check protection valve in the air brake 
system as shown in the schematic below.
9.  Start the engine and charge the air brake system again.  Turn the engine off.
10.  Locate and drain the secondary reservoir.  As this reservoir is drained, only the 
secondary gauge should indicate a pressure drop.  If both continue to drain, this 
indicates that the primary reservoir has a defective, or missing, single or one 
way check valve.
11.  Replace the existing, or install a new, single check valve in the primary reservoir 
supply port.  
Delivery 
Port
Control Port 
Compressor
Secondary
Reservoir
SC-PR
Single Check Protection Valve
Primary 
Reservoir
Engine Turbo
Exhaust
Port
Turbo Cutoff 
Governor
Supply 
Reservoir
WARNING:  Be sure to follow all the General Safety 
Guidelines outlined in the AD-SP
®
 Service Data Sheet,   
SD-08-2415, before performing any service on the air 
brake system.
Bendix
®
 AD-SP
®
 Air Dryer System
AD-SP
®
 Air Dryer
Purge Cycle
BW2763 ©  2009 Bendix Commercial Vehicle Systems LLC, a member of the Knorr-Bremse Group • All Rights Reserved • 5/09 • Printed in U.S.A.