BENDIX BW2263 Dépliant

Pagina di 2
1
®
SD-08-2401
Bendix
®
 AF-3
 In-Line Filter
FIGURE 1 - 
AF-3
™ 
 IN-LINE FILTER SECTIONAL AND EXTERIOR VIEW
SUPPLY
DELIVERY
SCREEN
DIRECTIONAL ARROW -
INDICATES AIR FLOW
1/4" NPT
SUPPLY
1/4" NPT
DELIVERY
DESCRIPTION
GENERAL
The AF-3
 in-line filter assembly is designed to prevent
foreign material from entering the control port of the Trailer
ABS modulator or spring brake relay.  The filter body is made
of steel with an internal screen element of stainless steel held
in place by a spring.  The filter is capable of removing particles
0.012 inches in size or larger. The filter has a ¼ NPT female
supply port and a ¼ NPT male delivery port.  Note:  If the
filter is installed in the reversed direction, its filtering
capability will be reduced.
WARNING! PLEASE READ AND FOLLOW
THESE INSTRUCTIONS TO AVOID PER-
SONAL INJURY OR DEATH:
When working on or around a vehicle, the following
general precautions should be observed at all times.
1. Park the vehicle on a level surface, apply the park-
ing brakes, and always block the wheels.  Always
wear safety glasses.
2. Stop the engine and remove ignition key when
working under or around the vehicle.  When work-
ing in the engine compartment, the engine should
be shut off and the ignition key should be removed.
Where circumstances require that the engine be
in operation, EXTREME CAUTION should be used
to prevent personal injury resulting from contact
with moving, rotating, leaking, heated or electri-
cally charged components.
3. Do not attempt to install, remove, disassemble or
assemble a component until you have read and
thoroughly understand the recommended proce-
dures.  Use only the proper tools and observe all
precautions pertaining to use of those tools.
4. If the work is being performed on the vehicle’s air
brake system, or any auxiliary pressurized air sys-
tems, make certain to drain the air pressure from
all reservoirs before beginning ANY work on the
vehicle.  If the vehicle is equipped with an AD-IS
air dryer system or a dryer reservoir module, be
sure to drain the purge reservoir.
SPRING