11.0 Maintenance
It is recommended that the following checks are carried out
on an annual basis:
1) Check the collector installation for any signs of damage or 
any build up of debris.
2) Check for any corrosion to the collector or the mounting 
system and repair if necessary. 
3) Check the tightness of the fasteners. Where fasteners 
cannot be readily accessed, the overall security of the
collector installation may indicate whether problems exist.
4) Check the fittings and pipe work for any signs of fluid 
leakage or damage, including the condition of the pipe 
insulation, and repair if necessary. Check inside the building 
for any evidence of leaks.
5) Examine the roof tiles around the collector installation for 
any damage or deterioration, and repair if necessary.
6) Check for any foliage growth that may cause shading of the
collectors.
7) Where applicable, check the condition of any ballast used 
to secure the system.
8) In areas where there may be a build up of dirt on the 
collector, only non-abrasive cleaning materials and methods
should be used to clean the collectors and mounting 
system components.