Behringer Eurolight LD6230 Istruzione Sull'Installazione

Pagina di 6
5
EUROLIGHT LD6230 Installation Instructions
◊ 
Please make sure that each dimmer load is connected to a separate 
channel. Never connect more than one output to just one common 
neutral conductor. 
◊ 
ATTENTION: Due to electrocution danger, do not use your dimmer pack 
if there are bare cables visible.
Connection Options for Flexible Usage
Output Connector (HARTING)
In the back of your LD6230 there is a cable bushing for connecting your 
illuminants. Open the flap on the top of the LD6230 to get to the terminal clamps 
used for this purpose. Here you have the option to retrofit a 16-pin HARTING 
connector. To do that, you first have to remove the back-bearing cover sheet and 
connect the HARTING connector to the terminal clamps.
PIN assignment/HARTING connector
PIN 1
Phase channel 1
E1 PIN 9
Neutral channel 1
N
PIN 2
Phase channel 2
E2 PIN 10
Neutral channel 2 
N
PIN 3
Phase channel 3
E3 PIN 11
Neutral channel 3 
N
PIN 4
Phase channel 4 
E4 PIN 12
Neutral channel 4
N
PIN 5
Phase channel 5
E5 PIN 13
Neutral channel 5
N
PIN 6  Phase channel 6
E6 PIN 14
Neutral channel 6
N
PIN 7
free
PIN 15
free
PIN 8
free
PIN 16
free
Ground wires need to be fastened to their respective PE connectors
CEE Power Supply Connector
Also located in the back is a cable bushing for the mains supply. Here, you can 
retrofit a 5-pin CEE 32 A mains connector by removing the back-bearing cover 
sheet and connect the CEE high-voltage connector to the connecting terminal. 
The following illustration shows how the connections are allocated: 
L3
L2
N
L1
CEE connector pin allocation 
◊ 
Removable mains connector cables with mains interconnections 
(pursuant IEC60320) must match the minimal load-carrying capacity 
of the connector or must comply with the IEC60799 standard. 
The interconnection and the cable must comply with prevalent 
nominal values (maximal voltage and current).
◊ 
During the installation, please adhere to the instructions provided by 
the connector manufacturer.
Specifications
Channels
Number 6
Load per channel 
0.2 A min./10 A max.
Maximal load per channel 
10 A using a 3-phase connector
Frequency 
50/60 Hz
Inputs
Power supply 
3-phase connector, internal 
terminal block/PG cable screw joint, 
CEE connector (optional installation by 
qualified personnel)
Analog 
0 to +10 V via 8 pin DIN
Digital 
DMX512 via XLR 5 pin
Outputs
Digital 
DMX512 via XLR 5 pin
Load 
Internal terminal block/PG cable screw 
joint, HARTING
®
 (optional installation by 
qualified personnel)
System Fuses
Load securing per channel 
10 A cable protection switch (type C)
Control section fuse 
2 x T 100 mA H/250 V 1 x T 160 mA 
H/250 V for voltage range 220 - 230 V 
(EU) 2 x T 160 mA H/250 V 1 x T 315 mA 
H/250 V for voltage range 120 V (UL)
Power Supply
Voltage
USA/Canada 
120 V~, 60 Hz
Europe/U.K./Australia 
240 V~, 50 Hz
Maximum power consumption 
3 x 20 A
Dimensions/Weight
Dimensions (H x W x D) 
approx. 3 1/3 x 19 x 15 9/10" 
approx. 84.3 x 482.6 x 403.8 mm
Weight 
approx. 21.6 lbs / 9.80 kg
BEHRINGER continuously strives to assure the highest quality standards possible. Required modifications may 
be implemented without prior notice. Technical data and the appearance of the unit may deviate from the above 