Burnham Flash Separator Dépliant

Pagina di 2
Flash Separator
   Reduces steam pressure or vents process steam  
directly to atmosphere.
   Eliminates moisture from process steam (cyclonic  
spinning mechanism permits the use of smaller tanks 
to completely separate flash steam from condensate).
   ASME Section VIII “UE” stamped separator standard  
up to model BFS-16-56.
   ASME Section VIII “U” stamped separator standard for 
models BFS-16-56 and above.
   Sized to accommodate a given #/hour flow rate of 
steam from a given source psig to a given vent psig.
   Model Range: 
6" diameter x 34" high through 
36" diameter x 108" high
   Modular configuration to meet customer requirements 
include: a flash separator and the following options: 
trap, check valve, ball valve, safety relief valve and 
gauge glass.
   Can be custom configured to meet customer  
requirements.
   Stainless steel striking plate standard.
*Flash Separators over 18" diameter, 
cleanout will be 2" NPT coupling.
Follow the “Pressure From...” down vertically on the chart above to the “Pressure To...”.
EXAMPLE:  75 PSIG condensate flashed to low pressure heating system at 15 PSIG gives 7.6% condensate flashed into system.
After determining the percent of flash from  
the chart to the right, determine the size of  
Flash Separator from the chart on the back.
EXAMPLE: Referring back to the chart to  
the right, you have a 7.6% flash, if you have  
30,000 #/hour condensate at 75 PSIG,  
2,280 #/hour steam (30,000 x .076). Locate  
30,000 in the left column of the chart on the  
back, go across to 2,280 #/hour flash steam  
column (3,000). You would use a 56" high x  
18" diameter Flash Separator with a 3" draft  
and 5" vent.
I
Inlet - Specify inlet to match your return line or blowoff line
H
34
56
72
96
108
DIA.
6
8
10
14
16
18
20
24
30
36
D
1
1-1/4
1-1/2
2
2-1/2
3
4
5
V
2
2-1/2
3
4
5
6
8
10
12
14
16
18
PL
5/16
3/8
DIMENSION CHART MODEL BFS
Pressure To...
800
700
600
500
400
300
200
100
75
50
25
700
600
500
2.5
5.2
7.9
2.7
5.5
2.9
-
-
-
-
-
-
-
-
400
300
200
10.8
14.1
18.0
8.5
11.9
15.8
6.0
9.4
13.5
3.2
6.7
10.9
3.7
7.9
-
-
-
-
-
-
100
50
30
23.1
26.9
29.0
21.0
24.9
27.0
18.8
22.7
24.9
16.3
20.4
22.6
13.5
17.6
19.9
10.2
14.4
16.7
6.0
10.4
12.8
4.6
7.1
2.5
5.1
2.6
-
15
7
0.0
31.1
32.6
34.3
29.2
30.7
32.4
27.1
28.6
30.4
24.8
26.4
28.2
22.2
23.8
25.6
19.0
20.7
22.5
15.2
16.9
18.7
9.6
11.3
13.3
7.6
9.4
11.9
5.2
7.0
9.0
1.8
3.7
5.8
PRESSURE FROM...