Status Indicators
 
 
Control Power ON
 Located on the control panel (top center), this indicator is illuminated whenever input
power is present and the power supply interlock switch is engaged.
 
 
High Voltage Neon Lamp
 Located on the high voltage circuit (top) board, this lamp indicates that the high
voltage circuits are active.
 Extreme caution should be used if the neon lamp is on.
 
 
Flashhead Alarm Status LED
 Located on the sync/monitor (middle) board, this LED will be green when the
flashhead is operating correctly.
 If the LED is off, the system is in alarm mode.
 
 
Sync Out LED
 Located on the sync/monitor (middle) board, this LED blinks red to indicate that a
sync signal has been generated.
 In a multiple flashhead system, only the sync/monitor board that is set as the master
will blink this LED.
 
 
Sync In LED
 Located on the trigger/control (bottom) board, this LED blinks green to indicate that a
sync signal has been received from the sync/monitor board.
 
Tools Required
 
 Flat head screwdriver
 5/16” nutdriver to open flashhead
 Clean gloves to use when changing flashtubes
 Digital multimeter w/ Ohm reading and 500 VDC capacity
 NE2 neon light, Radio Shack catalog number 272-1102, Honeywell part # 77-2342
 Short piece of wire for jumper (Approx. #12 wire gauge)