IMPORTANT SAFETY INFORMATION
Your safety and the safety of others is very important.
Important safety messages have been provided in this Job Aid. Always read and obey all
safety messages.
   This is the safety alert symbol.
   This symbol alerts you to hazards that can kill or hurt you and others.
   All safety messages will be preceded by the safety alert symbol and the word
   “WARNING.”
All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell
you what can happen if the instructions are not followed.
GENERAL INFORMATION
IMPORTANT MODEL & SERIAL
NUMBER INFORMATION
The Direct Spark Ignition System is used on
Whirlpool  gas  ranges  produced,  beginning
January 3, 2000, Serial Code RK02. The Model
number of these units will be a “-5” version of
the current G-line gas range.
Example: SF365PEGQ5
This Direct Spark Ignition System will only be
available on self-cleaning gas ranges.
ELECTRICAL REQUIREMENTS
The supply voltage is critical for proper opera-
tion of the Direct Spark Ignition (DSI) System.
The requirements are 102 to 132 VAC with the
proper polarity and ground. If the electrical sup-
ply is less than 102 VAC, sparking will not be
reliable.  If  the  system  is  over  132  VAC,  per-
manent damage to the DSI can occur.
NOTE TO TECHNICIAN: Improper polar-
ity  will  cause  the  direct  spark  ignition
system to malfunction. Always check for
proper polarity at the wall outlet before
replacing parts.
Proper  polarity  must  also  be  supplied.  If  the
supply polarity is reversed, the DSI control will
not be able to detect the presence of a flame.
Reverse polarity will not affect the cooktop op-
eration, but the Bake and Broil burners will fail
to remain lit.
A proper ground is also required. The DSI con-
trol generates a significant amount of electri-
cal noise. This noise is minimized  by clamp-
ing the noise to ground. If a proper ground is
not connected, the ERC may periodically dis-
play  “PF,”  which  means  that  a  reset  has  oc-
curred in the ERC.
GAS REQUIREMENTS
Gas supply pressure should be a minimum of
7˝ water column pressure for natural gas, and
11˝ water column pressure for L.P. gas. How-
ever, the gas distribution valve should main-
tain 4˝ water column pressure for natural gas,
and 10˝ water column pressure for L.P. gas.