Bunn Single SH DBC* (with Smart Funnel) Manuale Proprietario
Page 29
NEW SPRAY FLOW
XX.X OZ/M
ENTER OZ XX.X
(-) DONE (+)
CALIBRATE FLOW?
NO YES
SPRAYHEAD CAL?
NO YES
CONTAINER RDY?
QUIT YES
CALIBRATE SPRAY
PRESSBREWSTART
CALIBRATE SPRAY
60 SEC TO FINISH
COUNTS DOWN
TO ZERO
AFTER 1 MINUTE
BREW PRESSED
EXIT TO THE
NEXT FUNCTION
SCREEN
CALIBRATE FLOW
This function allows the operator to enter the actual
flow rate of the sprayhead and the bypass by dispens-
ing both separately for one minute. The volumes are
then entered in ounces per minute. (Oz/M)
Procedures to calibrate the sprayhead flow rate:
1. Place a container, accurately graduated in ounces,
and with a minimum capacity of 60 ounces, beneath
the funnel on the brewer.
2. Press and hold the ® pad until the display reads
SET NEW RECIPES. Release the ® pad. Press and
release the ® pad until the display reads CALIBRATE
FLOW.
3. Press and release YES to advance to the SPRAY-
HEAD CAL? function screen. (Pressing NO in the
CALIBRATE FLOW screen will advance to the next
function screen, BREW COUNTERS).
4. Press and release the YES pad. The display should
read CONTAINER READY? If the container is under
the funnel, press YES. The display should read
CALIBRATE SPRAY .. PRESS BREW TO START.
5. Press and release the
pad. The display should
read CALIBRATE SPRAY .. 60 SEC TO FINISH. The
60 second timer on the display will count down to
zero. When the counter reaches zero, the display
will change to ENTER OZ., along with a number
measured in ounces per minute.
6. Measure the amount of water in the container and
using the (-) or (+) pads, adjust the amount on
the display to match the amount in the container.
Then press DONE.
7. The display should now read NEW SPRAY FLOW,
along with the correct flow rate of the sprayhead
in ounces per minute. After about 5 seconds,
the display will return to the CALIBRATE FLOW
screen.
8. To exit the CALIBRATE FLOW program, press NO
to advance to the next function screen, or press
the
pad located on the front switch panel to
exit the CALIBRATE FLOW function and return to
the MAIN SCREEN.
P2307
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
34025 022509